SPECIFICATIONS
WIRING
DIAGRAM
101487
Output Rating (kW / BTU/Hr)
Fuel
Fuel Tank Capacity
(Liters/U.S. Gal.)
Fuel Consumption
(Liters Per Hr./Gal. Per Hr.)
Electric Requirements
Amperage (Normal Run)
Hot Air Output (CMM/CFM)
RPM
Orange
Ignitor
Motor
Green/
Yellow
Red
Black
Black
Start
Capacitor
Run
Black
Capacitor
44kW/150,000
Use Only Kerosene or No. 1 Fuel Oil
51.09/13.5
4.16/1.10
230 V/50 Hz
1.5
17/600
2850
230V/50Hz
Blue
Brown
Green/
Yellow
Terminal
Board
Blue
White
Spark Plug
White
Terminal
Board
Red
Red
S or 2
M or 3
Motor
Start
Relay
Black
L or 1
Figure 19 - Wiring Diagram
Brown
White
B
Safety
Blue
Blue
Control
Photocell
Red
R
Reset
Button