6.5

Switching the thread tensioner on/off

Correct thread interlacing in the center
of the material
Needle-thread tension too low
or
hook-thread tension too high
Needle-thread tension too high
or
hook-thread tension too low
All machines
When pulling the hand lever (1) towards the operator, the
tensioners (3) and (4) are switched off.
Tensioner (2) is never switched off.
Manually controlled machines (without the thread trimming)
Tensioners (3) and (4) are mechanically switched off when the foot
is lifted with a hand or knee lever.
Machines with the thread trimming
Tensioners (3) and (4) are switched off with an electric magnet or
pneumatic cylinder at the foot automatic lifting. If the automatic foot
lifting at the machine stop is pre-selected, the tensioners are
switched off, but temporarily only, so that the switching off electric
magnet does not overheat.
Tensioners (3) and (4) are also switched off temporarily during the
trimming cycle.
Tensioners (3) and (4) are not switched off at the foot lifting with
the hand or knee lever.