Second Communicator Options; Third Communicator Options; Fourth Communicator Options; Downloading Option Codes - DSC PowerSeries PC1404 V1.1 Installation Manual

Dsc power series security systems installation guide
Table of Contents

Advertisement

[381] Second Communicator Options

Def.
Opt.
ON
1
Opening After Alarm Keypad Ringback Enabled
2
For Future Use
3
SIA Sends Programmed Reporting Codes
4
Closing Confirmation Enabled
5-6
For Future Use
7
Contact ID Uses Programmed Reporting Codes
8
For Future Use

[382] Third Communicator Options

Def.
Opt.
ON
1
For Future Use
2
Alarm Communications Enabled During Walk Test
3
Communications Cancelled Message Enabled
4
Call Waiting Cancel Enabled
5
For Future Use
6
AC Failure Communications Delay is in Hours
7
Number of Dialing Attempts for Residential Dial is 1
8
For Future Use

[383] Fourth Communicator Options

Def.
Opt.
ON
1
For Future Use
2
Phone Number 2 Backs up PH#1
3
Phone Number 3 Backs up PH#2
4
Phone Number 4 Backs up PH#3
5
FTC Events Communicate
6
For Future Use
7
For Future Use
8
For Future Use
DLS Downloading

[401] Downloading Option Codes

Def.
Opt.
ON
1
Answering Machine/Double Call Enabled
2
User Can Enable DLS Window
3
Call-Back Enabled
4
User Initiated Call-Up Enabled
5
Auto Event Buffer Upload Enabled
6
300 Baud Panel Call-Up
7
For Future Use
8
For Future Use
5 Programming Worksheets
OFF
Opening After Alarm Ringback Disabled
SIA Sends Automatic Reporting Codes
Closing Confirmation Disabled
Contact ID Uses Automatic Reporting Codes
OFF
Alarm Communications Disabled During Walk
Test
Communications Cancelled Message Disabled
Call Waiting Cancel Disabled
For Future Use
AC Failure Communications Delay is in Minutes
Number of Dialing Attempts for Residential Dial
is 5
OFF
Phone Number 2 is Dedicated
Phone Number 3 is Dedicated
Phone Number 4 is Dedicated
FTC Events Do Not Communicate
OFF
 
Answering Machine/Double Call Disabled
User Cannot Enable DLS Window
 
Call-Back Disabled
 
User Initiated Call-Up Disabled
 
Auto Event Buffer Upload Disabled
 
110 Baud Panel Call-Up
 
 
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents