[381] Second Communicator Options
Def.
Opt.
ON
1
Opening After Alarm Keypad Ringback Enabled
2
For Future Use
3
SIA Sends Programmed Reporting Codes
4
Closing Confirmation Enabled
5-6
For Future Use
7
Contact ID Uses Programmed Reporting Codes
8
For Future Use
[382] Third Communicator Options
Def.
Opt.
ON
1
For Future Use
2
Alarm Communications Enabled During Walk Test
3
Communications Cancelled Message Enabled
4
Call Waiting Cancel Enabled
5
For Future Use
6
AC Failure Communications Delay is in Hours
7
Number of Dialing Attempts for Residential Dial is 1
8
For Future Use
[383] Fourth Communicator Options
Def.
Opt.
ON
1
For Future Use
2
Phone Number 2 Backs up PH#1
3
Phone Number 3 Backs up PH#2
4
Phone Number 4 Backs up PH#3
5
FTC Events Communicate
6
For Future Use
7
For Future Use
8
For Future Use
DLS Downloading
[401] Downloading Option Codes
Def.
Opt.
ON
1
Answering Machine/Double Call Enabled
2
User Can Enable DLS Window
3
Call-Back Enabled
4
User Initiated Call-Up Enabled
5
Auto Event Buffer Upload Enabled
6
300 Baud Panel Call-Up
7
For Future Use
8
For Future Use
5 Programming Worksheets
OFF
Opening After Alarm Ringback Disabled
SIA Sends Automatic Reporting Codes
Closing Confirmation Disabled
Contact ID Uses Automatic Reporting Codes
OFF
Alarm Communications Disabled During Walk
Test
Communications Cancelled Message Disabled
Call Waiting Cancel Disabled
For Future Use
AC Failure Communications Delay is in Minutes
Number of Dialing Attempts for Residential Dial
is 5
OFF
Phone Number 2 is Dedicated
Phone Number 3 is Dedicated
Phone Number 4 is Dedicated
FTC Events Do Not Communicate
OFF
Answering Machine/Double Call Disabled
User Cannot Enable DLS Window
Call-Back Disabled
User Initiated Call-Up Disabled
Auto Event Buffer Upload Disabled
110 Baud Panel Call-Up
29