4. INSTALLING OPTIONAL EQUIPMENT (for RADAR)
4.2.1
Mounting
Fasten the junction boxes to the mounting location with four sets of M8 bolt and nut.
4.2.2
Cable fabrication
RW-9600
4-10
514
474
NAMEPLATE
360
430
5
20
approx. 450
Armor
Pull out inner cables from here.
Vinyl sheath
Shield
60
Mass: 12kg
Units: mm
Shield
6
14 5 9
Coaxial cable
Crimp on lug for M8
FIXING HOLES
4-ø10