Upgrading To A Gv2 Series Control Panel - Bosch D7212GV2 Release Notes

Version 7.07
Hide thumbs Also See for D7212GV2:

Advertisement

D7212GV2
3.3
Version 7.01
3.3.1
D1260 Keypad Enhancements
The D1260 Keypad must have firmware version 1.03
or above to operate with the GV2 Series Control
Panels. An update kit (P/N: R19-D1260-0103) is
available from Customer Service: (800) 289-0096.
Custom Function Enhancements: The custom
functions now support the soft keys (the eight
unmarked keys around the display) on the D1260
Keypad. This change makes the operation of custom
functions on D1260 Keypad easier to program.
D1260 Keypads with firmware version 1.03 or above
do not need to check the control panel firmware
revision when communicating with GV2 Series
Control Panels; therefore, the Display Revision
(COMMAND 59) keypad (command center) function
can be password protected.
3.3.2
New Firmware Features:
Two Man Rule: Two Man Rule requires two unique
passcodes to be entered at the same keypad to disarm
an area. Without the second passcode, the system
denies entry. Two Man Rule requires the presence of
two people at opening, providing added security.
Early Ambush: Early Ambush requires two passcode
entries on the same keypad or on two separate
keypads located in the same area. Enter the same
passcode twice or enter two unique passcodes,
depending upon the configuration. The first entry
disarms the area and the second entry stops a timer
programmed to send a duress event. If the second
entry does not occur within the preset time, the
system generates a duress event. Early Ambush allows
users to inspect the premises and use the system to
confirm that the area is safe to enter, providing added
security.
Easy Exit Control: The D7212GV2 changes from
one armed state to another armed state without
disarming. For example, if you change the state from
Master Arm to Perimeter Arm, the control panel
complies and reports the change. Easy Exit Control
reduces the number of keystrokes and simplifies
system operation.
Passcode-Controlled Menus: The system prompts a
user to enter a passcode before viewing the keypad
function list menu. The system shows the user the
menu options allowed according to the user's
authority level. Passcode-controlled menus simplify
system operation by providing a user with unique and
pertinent options and information. This feature is not
intended for use on D1256 Fire Keypads.
F01U009079-04
Passcode Follows Scope: Use Passcode Follows
Scope to restrict passcode arming and disarming only
to the keypad's immediate local area. Passcode
Follows Scope simplifies the arming and disarming
procedure without limiting any other keypad
command capabilities.
Invisible Walk Test: A function list menu item
allows the user to test invisible interior or perimeter
controlled and non-controlled (24-hr) points within the
scope of the keypad without sending a report to the
central station.
Latest Close Time: The Extend Close
(COMMAND 51) function is enhanced with a
programmable latest closing time.
4.0
Remote Programming Software (RPS) version 3.7.160
or above is required to upgrade an existing G Series
Control Panel installation to a GV2 Series Control
Panel. Because the GV2MAIN and GV2AUX
handlers cannot read the configuration data from a
G Series Control Panel, using RPS is the only method
available to convert an account's existing panel type
to a D7212GV2.
Refer to the RPS Help files for the specific control
panel for additional information on control panel
conversion. In the RPS help file, select:
Panel Specific Information 9000 Series
Control/Communicators Communicating with
9000 Series Panels Upgrading a Panel Type
Hardware Enhancements
D7212GV2 Release Notes for Version 7.07
Page 10
Upgrading to a GV2 Series
Control Panel
The control panel has an SDI bus quick-connect
®
terminal (Molex
connector) next to the S1 reset
switch. This connector provides an easy way to
connect an SDI device to the SDI bus without
disconnecting the wires on SDI Terminals 29
through 32. To order SDI wiring harnesses, use
the following part numbers: Molex
®
(P/N: C321) and Molex
(P/N: PKWH).
This SDI terminal is not compatible with
the D5200 Programmer.