Mitsubishi Electric MSH-18RV Service Manual page 78

Split-type, heat pump air conditioners
Table of Contents

Advertisement

OPERATING PROCEDURE
4. Removing the heat exchanger and compressor
(1) Remove the screws of the rear panel. Remove the screws
of the valve bed and the valve bed. (The valve bed is
fixed by the catches on the right and left sides. Lift it to
remove.)
Open the rear panel to the rear to remove.
NOTE :
All panels are fixed by catches, and must be removed by
up and down.
(2) Remove the screws of the side panel and the side panel.
(3) Remove the screws of the rear guard and the rear guard.
(4) Remove the screws of the separator support plate and
the separator support plate.
(5) Remove the screws of the motor support and the motor
support.
(6) Remove the relay panel.
Disconnect the fan motor lead wires.
(7) Remove the soundproof felt.
(8) Remove the screws of the separator and the separator.
(9) Recover gas from the refrigerant circuit.
(10) Remove the screws of the heat exchanger and the heat
exchanger.
Detach the welded part of pipe.
(11) Remove the nuts of the compressor and the compressor.
Detach the welded part of the suction pipe and the dis-
charge pipe.
Photo 5
Rear
panel
Screws
Photo 6
Accumulator
Photo 7
Stop valve
Compressor
Sound
proof felt
78
PHOTOS
Screws
Side
panel
Rear guard
Heat exchanger

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msh-24rvMuh-18rvMuh-24rvMuh-30rvMsh-30rv

Table of Contents