Mitsubishi Electric MSH-18RV Service Manual page 7

Split-type, heat pump air conditioners
Table of Contents

Advertisement

Indoor model
Function
Power supply
Capacity
Dehumidification
Air flow(High)
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Fan motor current
Coefficient of performance(C.O.P)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
Sound level (High)
Fan speed (High)
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Thermistor RT13(at25:)
Outdoor model
Capacity
Air flow
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level(High)
Fan speed(High)
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
Thermistor RT61(at0:)
Thermistor RT62(at25:)
Thermistor RT63(at0:)
NOTE:Test conditions are based on JIS C 9612.
Cooling : Indoor
DB 27°C / WB 19°C
Outdoor DB 35°C / (WB 24°C)
Cooling
kW
R/h
K /h
A
A
15.3-15.5
W
3,300-3,460
A(kW)
%
A
A
2.52-2.40
"
mm
kg
dB
rpm
k"
k"
k"
K /h
A
14.41-14.57
A
W
"
"
mm
kg
dB
rpm
kg
cc
k"
k"
k"
Heating : Indoor
Outdoor DB 7°C / WB 6°C
MSH-30RV -
Single phase
220-240V, 50Hz
8.3
4.5
960
25
98-93
82-84
0.33-0.35
RC4V40-AA
WHT-BLK 138.2
BLK-RED 159.0
1,100O325O227
16
5
47
1,280
3
10
10
10
MUH-30RV -
2,880-3,000
0.56-0.58
NH-56VNHT
2,700
C-R 0.66
C-S 1.58
RA6V75-AA
WHT-BLK 62.8
BLK-YLW 55.9
YLW-RED 26.0
870o850o295
79
55
790-820
2
2.30
1,200 (MS32N1)
33.18
231.44
33.18
DB 20°C / WB 15.5°C
7
E1
Heating
9.6
960
16.3-15.8
3,520-3,560
98-94
2.73-2.70
E1
15.41-14.87

Hide quick links: