Lennox Montebello MDLX40IN-PV Installation Instructions Manual page 25

Montebello dlx series power vent direct-vent gas fireplaces
Hide thumbs Also See for Montebello MDLX40IN-PV:
Table of Contents

Advertisement

LENNOX HEARTH PRODUCTS • MONTEBELLO
Burner Air Shutter Adjustment Procedure
WARNING
• Air shutter adjustment
should only be performed
by a qualified professional
service technician.
• Ensure that the front glass
door assembly is in place
and sealed After adjustment.
CAUTION
Soot will be produced if the
air shutter is closed too much.
Any damage due to carboning
resulting from improperly
setting the air shutter is not
covered under the warranty.
To adjust the flame, move the adjustment air
shutter (located on the lower venturi) back or
forward to increase or reduce the air shutter
opening, respectively. Position the air shutter
to the factory setting as shown in Figure 41.
Allow the burner to operate for at least 15
minutes. Observe the flame continuously.
If it appears weak or sooty as previously
described, adjust the air shutter until the
flame appearance is as desired.
When satisfied that the appliance operates
properly, finish the installation. Leave the
ON/REMOTE/OFF wall switch in the REMOTE
position and turn the remote switch OFF.
Use the remote to adjust the flame height
as desired.
DLX POWER VENT DV GAS FIREPLACES (MDLX40/45IN-PV) • INSTALLATION INSTRUCTIONS
®
Main Burner Factory Air Shutter
Opening Setting—Inches (millimeter)
Model
Nat.Gas
MDLX40IN-PV
1/8 in. (3.18 mm)
MDLX45IN-PV
1/8 in. (3.18 mm)
Figure 41: Air Shutter Adjustment
Contemporary Media Shown (MDLX40)
Figure 42: Burner Flame Appearance
Rustic Oak Logs Shown (MDLX45)
Figure 43: Burner Flame Appearance
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Air Shutter
Opening
Venturi
Orifice
Gas
Valve
Burner
Venturi
25