Step 4. Field Wiring - Lennox Montebello MDLX40IN-PV Installation Instructions Manual

Montebello dlx series power vent direct-vent gas fireplaces
Hide thumbs Also See for Montebello MDLX40IN-PV:
Table of Contents

Advertisement

LENNOX HEARTH PRODUCTS • MONTEBELLO

Step 4. FIELD WIRING

CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat
et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois
l'entretien terminé.
CAUTION: Ground supply lead must be connected to the wire
attached to the green ground screw located on the outlet
box. See Figures 27 and 28 on Page 20. Failure to do so will
result in a potential safety hazard. The appliance must be
electrically grounded in accordance with local codes or, in the
absence of local codes, the (USA) National Electrical Code,
ANSI/NFPA 70—latest edition, or the Canadian Electrical
Code, CSA C22.1—latest edition.
Route Cable
NOTE: Electrical wiring must be performed by a qualified electrician.
• Install the strain relief in the hole provided on the right side of
fireplace for the electrical wiring (see Figure 20).
• Either use the intgrated junction box, or position an electrical
junction box (not provided) within reach of the termination wiring
pigtail (see Figure 23 on Page 19). Route the pigtail to the junction
box as the termination is installed.
• Route 14 gauge AWG grounded solid wire Romex
stranded cable (e.g., SJOT) from the fireplace to the newly installed
junction box near the termination. Ensure the cable is safety
plated to prevent damage from framing nails and finish drywall
screws. Route it into the lower control compartment and cut to
length before installing the terminals. Install provided hardware on
the ends of the cable. Cable is not provided. The provided crimp
terminals are intended for use with stranded cable. If using Romex,
connect per National Electric Code or local code.
Strain
Relief
14 Gauge
Grounded
Romex or
similar
Stranded
Cable
Vacuum
Hose
Snap
Bushing
Wall Switch
Harness
Figure 20: Routing Wiring
18
DLX POWER VENT DV GAS FIREPLACES (MDLX40/45IN-PV) • INSTALLATION INSTRUCTIONS
®
• Refer to Figure 25 on Page 19 and install the electrical hardware
on the ends of the cable. Male terminals on the Black and White
wires, and ring terminals on the ground wire.
• Using standard electrical practices and the terminals provided,
connect the three wires of the cable to the termination pigtail
within the Electrical junction box. Ensure ground.
• The fireplace end of the cable will be addressed in Connecting
The Power Vent To The Fireplace Control System.
Figure 21: Vacuum Hose Connection to Probe
or equally-sized
®
Right Side
of Fireplace
Junction Box
Figure 22: Vacuum Hose Connection to Pressure Switch
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Probe (1 *)
Adaptor Assembly
* See Figure 11 on Page 12
Vacuum Hose
Pressure switch is located
behind the panel on the right
side of firebox
Firebox
Pressure Switch
NOTE: Pressure switch style may vary from that shown.
Hose Clamp (7 *)
Vacuum Hose (2 *)
Pressure Switch
Vacuum Hose