Grounding The Device; Connecting To The Device - Siemens RUGGEDCOM RS8000 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS8000:
Table of Contents

Advertisement

RUGGEDCOM RS8000
Installation Guide
Figure 7: Failsafe Alarm Relay Wiring
1. Normally Open
2. Common
Section 2.4

Grounding the Device

The RS8000 chassis ground terminal uses a #6-32 screw. It is recommended to terminate the ground connection
with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in).
Figure 8: Chassis Ground Connection
1. Stainless Steel Stud
Section 2.5

Connecting to the Device

The following describes the various methods for accessing the ROS console and Web interfaces on the device.
For more detailed instructions, refer to the ROS User Guide for the RS8000.
Serial Console Port
Connect a PC or terminal directly to the serial console port to access the boot-time control and ROS console
interface.
Grounding the Device
3. Normally Closed
2. #6-32 Screw
3. #6 Ring Lug