NEC Univerge SV8100 Features And Specifications Manual page 1248

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 12.0
Program
Program Name
Number
11-15-16
Service Code Setup,
Administrative (for Special
Access) – Outbound IP Connect
for Programming
90-10-01
System Alarm Setup – Alarm
Type
90-69-01
Outbound IP Connection Setup –
Port Number
90-69-02
Outbound IP Connection Setup –
IP Address
90-69-03
Outbound IP Connection Setup –
Caller ID
Operation
Outbound IP Connection
1.
Open PC Pro (V6000 or higher) on PC that has same IP address as assigned in Program
90-69-02.
2.
Go to Communications/Connect.
2 - 1218
Description/Comments
Assign the service code for
Outbound IP Connection for
Programming. This Service Code
is used to invoke TCP
establishment request from
SV8100 to remote PCPro.
Indicates the alarm type for Failure
of Outbound IP Connection for PC
Programming.
Define the port number used for
Outbound IP Connection for
Programming.
Define the IP Address that the
System will make the TCP
establishment request to. I.E. the
IP address of the PC with the
waiting PC Programming.
Define Caller ID number that the
system to compare with received
Caller ID.
UNIVERGE SV8100
Assigned Data
1
(default not assigned)
Alarm 58:
Failure of Connection
(Outbound IP
Connection)
Adding parameter:
01: Programming ses-
sion is already active
02: Not setting of IP
Address or Port
03: Caller ID is not
match.
10: Failure of getting IP
Address.
11: Socket Open Error
12: Socket Port Setting
Error.
13: TCP Session
Timeout
1~65535
(default = 8000)
0.0.0.0 ~
255.255.255.255
(default = 0.0.0.0)
Max 16 digit (0 - 9,
,
9)
#
(default = None)
PC Programming
Level
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents