Installing The Outdoor Unit; Connecting The Cables To The Outdoor Unit - Samsung AD18A1C09 Owner's Instructions & Installation Manual

Multi-split type room air conditioner (cool and heat)
Hide thumbs Also See for AD18A1C09:
Table of Contents

Advertisement

I
O
U
NSTALLING THE
UTDOOR
NIT

Connecting the Cables to the Outdoor Unit

36
E-
Two electric cables must be connected to the outdoor unit:
The assembly cable connecting the indoor unit to the outdoor unit.
The power cable connecting the auxiliary circuit breaker to the
outdoor unit.
1
Remove the terminal board cover on the side of the outdoor unit.
2
Connect the assembly cable to terminals 1 to 5 and connect the power
cable to the terminals A to B.
Each wire is labelled with the corresponding terminal number.
Ensure the wire number of the indoor unit and the terminal
number of the outdoor unit.
3
Connect the earth wires to the earth terminals.
Refer to the page 38 for further details on how to check
that earthing is correct.
4
Replace the terminal board cover, carefully tightening the screw.
5
Connect the power cable to the auxiliary circuit breaker.
1
2
3
Outdoor unit
(L)
(N)
COM
5
L N
3
1 2
3
5
Indoor
unit
A-unit
1
2
3
1
2
(L)
(N)
COM
(L)
(N)
A
B
Earth
terminal
1 2
1 2
Earth
terminal
Terminal block
Earth
E
terminal
Circuit Breaker
(Main Power supply cable)
Earth
5
terminal
3
Assembly cable
3
5
Earth
terminal
B-unit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ad26a1c13Ud18a1c2Ud26a1c2

Table of Contents