Fm Alignment - Marantz SR7200 Series Service Manual

Hide thumbs Also See for SR7200 Series:
Table of Contents

Advertisement

2-4. FM Alignment

Output of signal generator should not be greater than necessary to obtain an optimum output reading.
Signal generator modulation .................. MAIN : 53.5%, PILOT : 10% (K,N)
Signal frequency .......................................... 1kHz / Deviation : 40kHz (K,N)
Modulation frequency .................................. 90.1MHz, 98.1MHz, 106.1MHz
Switch ........................................................... press the BAND Button to FM
Step
Subject
1
Tunning
voltage
2
FM DET.0V
and
Distortion
Adj
3
STEREO
Separetion
4
Seek
stop level
MAIN : 90%, PILOT : 10% (U)
1kHz / Deviation : 75kHz (U)
Signal
Set
generator
frequency
setting
setting
87.5kHz
87.5kHz
108kHz
108kHz
98.1kHz
98.1kHz
98.1kHz
98.1kHz
98.1kHz
98.1kHz
Equipment
Adjustment
connection
point
DC voltmeter
AC voltmeter
FD1 , FD2
oscilloscope
R17
DC voltmeter
tape monitor
L/R
AC voltmeter
MIX coil CO4
oscilloscope
SVR02
DC voltmeter
tape monitor
L/R
AC voltmeter
SVR 01
oscilloscope
tape monitor
L/R
47
Adjust for
87.5 MHz : 1.35 ~ 1.65V
108.0 MHz : 6.5V ~ 8.5V
Minimize 0V and distortion
Minimize STEREO distortion
and Maximize separatio
Separation L to R
Separation R to L
Scan stop point to 22dBu