HOW TO OPERATE YOUR HEATER
The controller is factory set, therefore synchronise will not be necessary, however if
you have purchased the controller as a spare part then refer to the following.
NOTE
Initial setup, synchronising the controller to your Symmetry heater, required only if the
controller is purchased as a spare or replacement part.
Before proceeding with synchronisation ensure that the gas and electricity are
connected.
Two controllers CAN NOT be used at the same time!
Remote Controller -
Synchronisation
10
9
11
4
To restore factory default settings
Turning 'ON' and 'OFF'
Changing the temperature
Change between Celsius - °C and
Fahrenheit - °F
Change between manual,
automatic and flame modes
Rinnai Australia
Step 1. Turn the power off at the power point for a minimum of
30 seconds, synchronisation will not be possible
unless the minimum 30 seconds has been observed.
Step 2. Ensure the remote control is turned off, to turn 'OFF'
press and release the 'PWR' button once.
Step 3. Turn the power on at the power point, the power
operation indicator on
flash once. The controller can now be synchronised
with the heater.
Synchronisation MUST BE performed within 30
seconds of the power being turned on, if more than
NOTE
30 seconds has elapsed repeat steps 1 through 3.
Step 4. On the controller in quick succession press the
following sequence of buttons: 'P' > 'T' > 'T' > 'UP'.
The LCD display will show 'L/C' (Learn Code) for 2
seconds then return to the normal 'OFF' state display.
The power operation indicator
will flash once to indicate that synchronisation has
4
been accepted.
With the thermostat 'OFF', press the following sequence of
buttons 'P' > 'T' > 'T' > 'DOWN'
Press the 'OK' and 'PWR' button at the same time to turn 'ON'/
ignite the heater. This is a safety feature to reduce the chance
of young children being able to turn on the unit easily.
The unit first lights to pilot and then after a short period switches
to the 'HIGH' setting.
To turn 'OFF' press and release the 'PWR' button.
®
The Symmetry
has increments of 1° which can be changed
using the 'UP' and 'DOWN' buttons.
The temperature control range is 7 - 32°C
The thermostat temperature display can be set to °C or °F.
The default is °C.
With the thermostat 'OFF', press the following sequence of
buttons: 'P' > 'T' > 'T' 'A/M' to toggle between °C or °F.
Press and release the 'A/M' button.