About Output Device Programming (*79/*80 Menu Mode)

Output Devices:
Output Functions: The system also provides up to 48 installer-defined output functions, which can
NOTE: When navigating the *79 and *80 menus: The [
the next prompt. The [#] key is used to revert back to the last question to check or change an entry. Press
[
] to go forward again.
Output Device programming involves:
1. Use *79 Menu Mode to assign module and output numbers and map them to device addresses.
NOTE: You must map output devices using *79 Menu Mode before you can use *80 Menu Mode.
2. Use *80 Menu Mode to create output definitions, which control the output devices.

*79 Menu Mode: Output Device Mapping

Use this menu to assign Relay Module device addresses and specific relay numbers, and Powerline
Carrier unit numbers. The system is based on predefined module addresses for 4204 and 4229
modules. Refer to the table shown at the "Module Address" prompt on the next page and set the
modules' addresses (via module DIP switches) accordingly.
The following table shows how these outputs are identified.
Output Identification
This output...
Relays:
X-10 Device
Built-in Outputs
5-8
The system supports up to 16 relays and/or Powerline Carrier devices (X-10
devices) plus 2 built-in trigger outputs in any combination. These 18 "outputs"
are assigned to system-wide output numbers (01-18). Use *79 Menu Mode to
assign output numbers and map them to device addresses.
be assigned to any of the physical outputs. Therefore, the action of any one of
the outputs can be based on as many of these functions as desired. This lets a
single relay or X-10 device perform many functions.
Use *80 Menu Mode to define output functions.
is identified by...
the Relay Module's device address and the relay position on that module (i.e. the physical
relay number, 1-4, on that module).
a house ID (entered in data field *27) and the unit number of the device.
the output number assigned, 17 for trigger 1 and/or 18 for trigger 2.
] key is used to accept an entry and advance to