6.4.2 HEARTH INSTALLATION

When installing to a hearth the appliance riser must create a minimum clearance of 3 3/8" PLUS the height of
the hearth from the fi nished fl oor to the bottom of the appliance.
STAND-OFF
CLEAN FACE SURROUND KIT
CLEANFACE SURROUND
FINISHED
FLOOR
STEEL
HEADER
(SUPPLIED)
3
3
/
"
8
CLEARANCE
PLUS
HEARTH
HEIGHT
COMBUSTIBLE
MATERIAL
CEMENT BOARD
PANEL
(SUPPLIED)
6
1
/
"
2
MINIMUM
37
3
/
"
8
PLUS
HEARTH
HEIGHT
CLEAN FACE
SURROUND
HEARTH
3
/
"
8
FIREPLACE
RISER
HEARTH
STEEL
HEADER
(SUPPLIED)
STAND-OFF
FIREPLACE
RISER
KIT
3
3
/
"
3
/
"
8
8
FINISHED
CLEARANCE
PLUS
FLOOR
HEARTH
HEIGHT
39
W415-0899 / B / 03.13.12