Specification
circulation pumps and heads
Specification
circulation pumps and heads
Vitodens 300, 4.5 to 12.0 kW on request
Variable speed heating circuit pump
The pump speed and therefore the flow
rate is relayed to the pump, and is set by
the control unit subject to outside
temperature and switching times for the
central heating or reduced mode via an
internal data BUS.
Vitodens 300, 6.6 to 35.0 kW
Circulation pump VIUPE 60 BUS
Rated voltage
V ~
Rated current
A max.
A
min.
Power
W max.
consumption
W
min.
W
as delivered condition
W
26 kW
W
35 kW
Residual head of the integral circulation pump
450
40
400
350
30
300
250
20
200
L
150
10
100
50
0
0
0
100
Volume flow in litres/h
Curve Capacity
Setting
Circulation pump
Code address E 6
A
30 %
B
40 %
C
50 %
D
60 %
E
70 %
F
80 %
G
90 %
H
100 %
8
Individually match the minimum and
maximum speed plus the speed during
reduced mode to the existing heating
system using the control unit codes.
In the delivered condition, the minimum
pump capacity (code address E 7) is set to
30 %, and the maximum pump capacity
(code address E 6) to 50 % for 26 kW or to
70 % for 35 kW.
230
0.45
0.21
100
50
65
80
200
300
400
500
Example
H Vitodens 300, 6.6 to 26.0 kW
H Design temperatures 75/55 ºC
H Radiator heating system,
E 6:030
E 6:040
heat demand 20 kW
¢ Volume flow 860 litres/h K
E 6:050
E 6:060
H Pressure drop 150 mbar L
E 6:070
H Design point M
E 6:080
E 6:090
Optimum pump curve according to diagram:
C = code address E 6:050.
E 6:100
M
600
700
800
900
K
Using the diagram, the flow rate can be
adjusted to the respective system
conditions.
Matching the flow rate of the circulation
pump to the individual system conditions
reduces the power consumption of the
heating system.
H
E
D
B
C
A
1000
1100
1200
1300
VITODENS 300
G
F
1400