Viessmann VITODENS 300 Datasheet page 5

Gas fired condensing boiler 4.5 to 66.0kw as multi−boiler system up to 264kw
Hide thumbs Also See for VITODENS 300:
Table of Contents

Advertisement

Gas fired boiler
Rated output range
= 50/30 ºC
T
/T
V
R
= 80/60 ºC
T
/T
V
R
Connection values
relative to max. output
with gas
with H
uB
Natural gas E
9.45 kWh/m
3
34.01 MJ/m
Natural gas LL
8.13 kWh/m
3
29.25 MJ/m
LPG
12.79 kWh/m
3
46.04 MJ/m
*2
Flue gas values
Flue gas value group to G 635/G 636
Temperature (at a return
temperature of 30 ºC)
at rated output
at partial load
Temperature (at a return
temperature of 60 ºC)
Mass flow rate
for natural gas
at rated output
at partial load
for LPG
at rated output
at partial load
Available draught
Standard efficiency
at
= 40/30 ºC
T
/T
V
R
= 75/60 ºC
T
/T
V
R
Average condensate volume
for natural gas and
= 50/30 ºC
T
/T
V
R
= 80/60 ºC
T
/T
V
R
Internal diameter of pipe to
expansion vessel
safety valve
Condensate connection
Flue outlet
Ventilation pipe
*1
Rated output for DHW heating.
*2
Calculation values for sizing the flue gas system to EN 13384.
Flue gas temperatures measured as gross values at 20 ºC combustion air temperature.
The details for partial load refer to an output of 30 % of rated output. Calculate the flue gas mass flow rate accordingly when the
partial load differs from that stated above (subject to the burner mode).
The flue gas temperature at a return temperature of 30 ºC is decisive for sizing the flue gas system.
The flue gas temperature at a return temperature of 60 ºC is used to determine the application range of flue pipes with maximum
permissible operating temperatures.
" For the specification of DHW cylinders and Viessmann system design components, see separate datasheets.
VITODENS 300
*1
kW
4.5 12.0/16.0
kW
4 11
3
3
m
/h
3
3
m
/h
3
kg/h
ºC
ºC
ºC
kg/h
kg/h
kg/h
kg/h
Pa
mbar
%
%
litres/day
litres/day
DN
DN
Hose coupling
∅ mm
Internal ∅ mm
External ∅ mm
Gas fired boiler
6.6 26.0
8.7 35.0
12.2 49.0
6 23.7
8 32
11 44.6
2.65
3.52
3.08
4.10
1.94
2.59
G
/G
G
/G
G
52
51
52
51
52
45
45
35
35
70
70
47.3
63.2
11.8
15.7
46.4
61.0
11.5
15.4
100
100
1.0
1.0
109
109
104
104
11 13
15 17
14 19
8 10
10 12
11 15
20
20
15
15
20 24
20 24
20 24
80
80
125
125
Vitodens 300
Gas fired
combination boiler
16.6 66.0
15 60.1
4.90
6.69
5.64
7.77
3.62
4.94
/G
G
/G
51
52
51
35
40
33
35
65
70
81.2
110.6
21.1
27.7
78.2
106.7
18.0
26.6
100
100
1.0
1.0
109
109
104
104
23 28
18 22
20
20
20
20
20 24
100
100
150
150
6.6 26.0
6 23.7
2.65
3.08
1.94
G
/G
52
51
45
35
70
47.3
11.8
48.4
11.5
100
1.0
109
104
11 13
8 10
20
15
20 24
80
125
5