e-series troubleshooting guide
HTR MAY BE DRY: There is little to no water flow through the heater. Check
that the slice valves are fully open. Contact dealer for service.
HTR TOO HOT: One of the sensors has reached 118°F (48°C). Do not enter
the water. Contact dealer for service.
PRES BTTN TO RSET: Some codes require a button press or power to be
removed and restored.
SNSR BAL-- ANCE: The sensors are reading a temperature of 2°F (17°C) or
more. This can occur on a fresh fill, no corrective action required. Contact
dealer for service.
SNSR A: Sensor A is non-functional. Contact dealer for service.
SNSR B: Sensor B is non-functional. Contact dealer for service.
MEM FAIL: There is a problem with the firmware. Contact dealer for service.
MEM RSET: Memory has failed. Contact dealer for service.
CLOk FAIL: Clock has failed. Contact dealer for service.
CNFG FAIL: Contact dealer for service.
STUk PUMP: Water may be overheated (DO NOT ENTER THE WATER).
Contact dealer for service.
HOT FALT: A pump may be stuck on. Contact dealer for service.
CHEk PH: Maintenance reminder to check the water pH. Comes up every 7
days, press any button to reset.
CHEk CHEM: Maintenance reminder to check the water sanitizer level.
Comes up every 7 days, press any button to reset.
CLN FLTR: Maintenance reminder to clean the filter. Comes up every 30
days, press any button to reset.
CHNG WATR: Maintenance reminder to change the water. Comes up every
90 days, press any button to reset.
CLN COVR: Maintenance reminder to clean the cover. Comes up every 180
days, press any button to reset.
CHNG FLTR: Maintenance reminder to change the filter. Comes up every
365 days, press any button to reset.
MAINTENANCE & WATER CARE
Please see the Maintenance and Water Care information in the Marquis
Owner's Manual section.