NOTE WALL MOUNT BACKGUARD INSTALLATION
1.
First measure from top of back trim to 16 3/8"
to what will be the center of the mounting
brackets. (see Fig 1)
Secure both brackets to the wall
2.
using the screws included
3. Attach the shelf to the shelf support panels
with supplied screws.
4. Slide shelf into position and over brackets.
INSTALLATION INSTTRUCTIONS
ELECTRICAL SUPPLY, ALL RANGES
In sta l l a ti o n o f Al l C ul in a r i a n r a n g e to p s m u st
b e planned so that the rough-in of the junction
box for the receptacle or conduit connection allows for
maximum clearance to the rear of the unit.
This is especially critical if the junction box in the
wall is directly behind the junction box of the
unit when the unit is installed. To minimize binding
when the unit is connected to the receptacle or
junction box, orient the receptacle or conduit
connector, and slide back into position.
POWER REQUIREMENTS: 120VAC, 60 HZ single phase
CULINARIAN SERIES
30" RangeTop – 120V 15 Amps. Max.
36" RangeTop – 120V 15Amps. Max.
48" RangeTop – 120V 15 Amps. Max.
60" RangeTop – 120V 15 Amps. Max
CAUTION! Disconnect the electrical supply
cord from the wall outlet before servicing
the rangetop. Follow all governing codes and
ordinances when grounding. In the absence of
codes follow the National Electrical Codes
ANSI / NFPA No. 70 (current issue).
GROUNDING METHOD
The rangetop is factory fitted with a power supply and
cord with a three-prong grounding plug. It must be
plugged into a matching grounding type receptacle c o n -
n e c t e d t o a c o r r e c t l y p o l a r i z e d 1 2 0 V o l t circuit. If
the circuit does not have a grounding type receptacle, it is
the responsibility of the installer to have the existing
receptacle changed to a properly grounded and polarized
receptacle in accordance with all applicable local codes
and ordinances. The receptacle replacement shall be in
accordance with the national Electrical Code.
WARNING! The third prong SHOULD
NOT, under any circumstances, be cut
or removed!