Installation of Convertible Type Indoor Unit
2) Installation on the Wall
• Select and mark the position for fixing bolts and piping
hole.
Decide the position for fixing bolts slightly tilted to the
drain direction after considering the direction of drain
hose.
• Drill the hole for anchor nut on the wall.
• Drill the piping hole on the wall slightly tilted to the out-
door side using a ø70 hole-core drill.
• Secure the 'Install Plate' onto the wall with four anchor
bolts, washers and spring washers.
Before secure the Install Plates, select the bent direc-
tion of the 'Install Plate' to the inside or outside
according to the installation circumstances.
Installation of Convertible Type Indoor Unit
52
Wall
Indoor
Spring
Wall
washer
Nut
Washer
Anchor nut
Less than
12mm
1 2 3
6
Unit: mm
Outdoor
Unit: mm