Installation of Wall Mounted Type Indoor Unit
Bundle the piping and drain hose together by
wrapping them with cloth tape over the range
within which they fit into the rear piping housing
section.
Drain hose
8. Reroute the pipings and the drain hose across
the back of the chassis.
Piping for passage through
piping hole
9. Set the pipings and the drain hose to the back of
the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.
Tubing holder
2
Push
Installation of Wall Mounted Type Indoor Unit
10
Pipe
Vinyl tape
(narrow)
Wrap with
vinyl tape(wide)
1
Hook
10. Indoor unit installation
Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit
against the installation plate until the hooks engage
into their slots(clicking sound).