General; Dmc-5 - Furuno RC18xx Series User Manual

Rc18 series a3 gmdss console
Table of Contents

Advertisement

7. RC1840 Equipment Setup
7.2 DMC-5 (Optional Equipment)
Refer to the Operator's/Installation Manual, DMC-5

7.2.1 General

The setup and testing of the DMC-5 should be completed last. This unit
expects all equipment, in the console, to already be operational.
*Watch* Pos: NG 00:00
Manual input ? [ SET UP ] Key
1) After powering up the DMC-5 for the first time the screen should be as
shown above.
2) Press the [SET UP] key, then the 0 key four times.
3) Then press the [ENT] key.
7.2.2 VHF Input
*Watch* Pos: manu
1) Press the [SET UP] key, then the 4 [VHF] key.
2) Press the [SELECT] to highlight No.1, then press the [ENT] key.
7.2.3 MF/HF Input
*Watch* Pos: auto
VHF
1) The display should appear as shown above, if it does continue to step 2.
If the Pos: still shows NG, check the DMC-5 wiring and programming
of VHF No.1, which should be mounted in the console.
2) Press the [SET UP] key, then the 5 [MF/HF] key.
3) Press the [SELECT] key to highlight J3E, then press the [ENT] key.
00:00
00:00
7-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc1815Rc1825Rc1840Rc18 series

Table of Contents