Product Specifi Cation - Danfoss TS715 Si Installation & User's Instructions

Electronic single channel timeswitch
Hide thumbs Also See for TS715 Si:
Table of Contents

Advertisement

Installation Instructions
Please Note:
This product should only be installed by a qualifi ed
electrician or competent heating installer, and should be
in accordance with the current edition of the IEEE wiring
regulations.

Product specifi cation

Specifi cation
Power supply
Switching action
Switch rating
Battery back-up
Setting/Running Accuracy
Dimensions, mm (W, H, D)
Design standard
Control Pollution Situation
Rated Impulse Voltage
Ball Pressure Test
Installation
Remove wallplate from unit by unscrewing the two screws
on the bottom edge of the unit.
From the top left hand corner of the wallplate, there must
be clearances of at least 140 mm to the right, 15mm to the
left, 30mm above and 100mm below in order to mount
the plug-on module.
230V Model
230 Vac, ±15%,
50/60 Hz
1 x SPDT voltage free, Type 1B
24 - 230 Vac, 3(1)A
24 hours minimum
±1 minute
135 x 88 x 32
EN 60730-2-7
Degree 2
2.5kV
75°C
24V Model
24Vac, ±15%,
50/60Hz
3