Functional overview
– If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them
with your backup copies of the TPM content.
Hard disk drives
Up to four SATA hard disk drives, each with a maximum height of 1 inch, are
built into the drive cages. There is a wire connection to the controller.
The server comes with an onboard SATA controller.
Onboard SATA controller
A SATA controller is integrated on the system board; up to four SATA hard disk
drives can be connected to the controller. The LSI Embedded MegaRAID
software (SATA Software RAID) supports RAID levels 0, 1 and 10.
The SATA HDDs cannot be replaced during operation.
For more information on configuring the controller, see section
onboard SATA controller" on page
Accessible drives
The first (top) bay contains the server's DVD drive.
The 5.25-inch bay below is available for one additional accessible drive
(CD/DVD drives or RDX device).
The accessible drives cannot be replaced during operation.
Power supply
The server has a permanently installed power supply unit that adjusts
automatically to any mains voltage in the range 100 V - 240 V.
High level of availability and data security
When memory data is accessed, 1-bit errors are identified in the main memory
and automatically corrected with the error correcting code (ECC) method.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in
the event of an error and automatically "hides" the defective system
components.