Desa M36E(B,H) Owner's Operation And Installation Manual page 12

B-vent decorative electronic ignition gas fireplace
Table of Contents

Advertisement

3. Activate remote handset battery by re-
moving insulating tab on back of handset
(see Figure 15). Battery is included pre-
installed.
4. Once the battery is activated unit is ready
to use.
5. Replace front refractory access panel.
Figure 15 - Installing Battery into Back of
Handset
GAS LINE HOOK-UP
WARNING: Gas line hookup
should be done by your gas
supplier or a qualified service
person.
WARNING: Before you pro-
ceed, make sure your gas supply
is OFF.
A manual shutoff valve has been included in
the appliance's gas supply system. You may
consider installing an extra gas shutoff valve
outside appliance's enclosure (check with
local codes) where it can be accessed more
conveniently with a key through a wall as
shown in Figure 16.
In conformance with local codes, route a
1/2" NPT gas line to appliance through hole
in left side of firebox or sub-floor as shown
in Figure 17.
CAUTION: Do not kink flex-
ible gas line.
12
INstallatIoN
Battery Cover
12 Volt Battery
Back of
Handset
Pull to Remove
Insulation Tab
www.desatech.com
Continued
DESA Heating, LLC recommends that a black
iron gas line be routed from the gas source,
through a sediment trap (shown in Figure 18)
and into appliance. Once connected through
appliance, a flexible gas line may be used for
ease of installation to gas control valve (see
Figure 19, page 13).
Before connecting black iron gas line to inside
of appliance a sediment trap must be included
outside appliance between gas line and gas
shutoff valve. It must extend down 3" beyond
center of pipe. Prepare incoming black iron
gas line with teflon tape or pipe joint com-
pound (Check with local building codes).
Key
Typical Exterior Wall Gas
Shutoff Installation
Figure 16 - Manual Shutoff Valve
1/2" NPT
Incoming Black
Iron Gas Line
A
M36E(B,H),
M36EP(B,H
VM36E(B,H),
VM36EP(B,H)
A
8
/
5
8
Figure 17 - Routing Incoming Gas Line
Sediment
Trap (Not
Supplied)
Figure 18 - Sediment Trap
Installation
7"
7"
Alternate Gas Supply
Through Sub-Floor
M42E(B,H),
M42EP(B,H)
VM42E(B,H),
VM42EP(B,H)
" (21.9 cm)
10
Incoming
1/2" Gas Line
Permitted by
Local Codes
3" Min.
(7.6 cm)
Shutoff
Valve
Extension
/
" (26.7 cm)
1
2
108796-01T