Advertisement

Operating and installation instructions
Rangehood
DA 420 V, DA 420 V EXT
DA 424 V, DA 424 V EXT
en - AU, NZ
To avoid the risk of accidents
or damage to the appliance,
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 09 200 860

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 420 V

  • Page 1 Operating and installation instructions Rangehood DA 420 V, DA 420 V EXT DA 424 V, DA 424 V EXT en - AU, NZ To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time.
  • Page 2: Table Of Contents

    Miele|home ........
  • Page 3 Contents Operation with DSM 400 control module ......34 Potential free connection ......... 34 Connection to a light switch .
  • Page 4: Caring For The Environment

    Caring for the environment Disposal of the packing Disposal of your old appliance material or machine The transport and protective packing Electrical and electronic appliances / has been selected from materials which machines often contain materials are environmentally friendly for disposal which, if handled or disposed of and can normally be recycled.
  • Page 5: Warning And Safety Instructions

    Any other usage is at the owner's risk. requirements. Inappropriate use Miele cannot be held liable for damage can, however, lead to personal injury resulting from incorrect or improper use and damage to property.
  • Page 6: Technical Safety

    Faulty components must only be the data plate correspond to the on-site replaced by genuine Miele original electricity supply, otherwise the parts. The manufacturer can only appliance could be damaged. Consult guarantee the safety of the appliance a qualified electrician if in any doubt.
  • Page 7 These models may only be combined with a Miele external motor. This rangehood must not be installed and operated in mobile installations (e.g. on a ship).
  • Page 8 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
  • Page 9: Correct Use

    Warning and Safety instructions Correct use Do not use the rangehood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the rangehood. To avoid the danger of into the appliance and hindering its fire, do not flambé...
  • Page 10: Correct Installation

    Safety regulations prohibit the fitting of a rangehood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from Miele or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 11: Modes Of Operation

    Modes of operation . . . air recirculation: The rangehood works with (Applies to the DA 420 V only. A conversion kit and charcoal filter are required, which are available as . . . air extraction: optional accessories: see "Technical Data")
  • Page 12: Guide To The Appliance

    Guide to the appliance...
  • Page 13: Guide To The Appliance

    It can also be used to check and alter the operating hours counter. Available as an optional accessory for n Touch control for the charcoal recirculation mode (DA 420 V only) filter f Recirculation grille (DA 420 V only) (only for recirculation mode on the DA...
  • Page 14: Miele|Home

    Miele electric rangehood. cooktop with onset controls. This module must be installed by a...
  • Page 15: Operation

    Operation To switch the fan on Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III. ^ Press the On/Off touch control. ^ To set this option, both the fan and The fan runs at power level "II".
  • Page 16: Run-On Option

    Operation Run-on option It is advisable to run the fan for a few minutes after cooking has finished to neutralise any lingering odours in the The indicator lamps for fan power levels air, whether you are using air extraction I and IV will flash if the automatic or recirculation mode.
  • Page 17: To Switch The Lighting On

    Operation To switch the lighting on Safety cut-out The cooktop lighting can be switched Should the rangehood be left on, the on and off independently of the fan. fan will switch off automatically after 10 hours. The lighting will remain on. ^ Briefly press the lighting touch ^ Pressing the On/Off touch control will control to switch on the cooktop...
  • Page 18: Filter Operating Hours Counter

    Operation Filter operating hours counter Reading the filter operating hours counter The number of hours the appliance has been in operation is stored in memory. To check the percentage of time set already used: The indicator lamp for the grease filter ^ Press the On/Off touch control to touch control will come on after 30 switch the fan on.
  • Page 19 Operation Altering the grease filter operating hours counter The operating hours counter for the grease filter is set at 30 hours. The time The – / + control lamps show the time set can be lengthened or shortened: which has been set: you can choose 20, 30, 40 or 50 hours.
  • Page 20 Operation ^ Use the – / + touch controls to select Setting and altering the charcoal the desired time. filter operating hours counter (with recirculation mode) The charcoal filter is needed for recirculation mode. ^ Confirm the selection by pressing the The rangehood is set at the factory for extraction mode.
  • Page 21: Adjusting The Height Of The Canopy

    Operation Adjusting the height of the canopy The height adjustment feature on the canopy can be used to: – adapt the height of the rangehood to suit the installation conditions. – adjust the working area underneath the rangehood to the height of the user.
  • Page 22: Cleaning And Care

    Miele Chartered and abrasive sponges, as well as pot Agent, from Miele or via the internet at scourers or sponges which have www.miele-shop.com. been used previously with abrasive cleaning agents.
  • Page 23: Grease Filters

    To prevent immediate resoiling, the Original Miele care product for stainless The grease filters should be cleaned at steel can be purchased from Miele or at the latest when the Grease filter touch www.miele-shop.com. Apply sparingly control lights up.
  • Page 24 ^ To reset the operating hours counter ^ Do not wash at more than 65 °C. If a for the grease filters, press and hold Miele dishwasher is being used, in the Grease filter touch control for select the Sensor wash programme.
  • Page 25: Fitting And Replacing The Charcoal Filters

    Replacement charcoal filters can be – they are no longer effective in obtained from your Chartered Agent absorbing kitchen odours. or Miele. See back cover for contact details, It should, however, be replaced at least and "Technical data" for type and every 6 months.
  • Page 26: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the rangehood from the mains supply. Ensure that – it is switched off at the isolator, or – the screw-out fuse is removed (in countries where this is applicable). Exercise caution when changing halogen lamps.
  • Page 27: After Sales Service

    – your Miele Chartered Agent or – Miele You will find the telephone number and address of Miele on the back cover of the manual. Please quote the model and serial number when contacting Miele. These...
  • Page 28: Appliance Dimensions

    4) Possible height range for appliance in extraction mode (see "Installation"). 5) Ventilation grille positioned at the top for recirculation. DA 420 V (Ceiling fixing viewed from above) Exhaust connection C 150 mm (not needed for recirculation mode) The exhaust connection in the ceiling is not fixed in the centre.
  • Page 29: Safety Distance Between Cooktop And Rangehood (S)

    Appliance dimensions Safety distance between cooktop and rangehood (S) The minimum safety distances between the top of a cooker or hob and the bottom of the cooker hood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance: –...
  • Page 30: Installation

    Miele (see "Technical Make sure the ceiling is strong data"). It is supplied with its own fitting enough to bear the weight of the instructions.
  • Page 31: Extending Or Limiting The Adjustment Range

    Installation Extending or limiting the adjustment Ensure that the tower is held range securely while carrying out the The height range for the appliance can following steps. Danger of inury. be extended or limited by moving the limit switch. It may be necessary to do this if –...
  • Page 32 Installation ^ Secure the limit switch opposite the guide on the telescopic tower (see illustration). ^ Raise and lower the canopy and check that the limit switch is working. ^ Loosen the top limit switch. ^ Remove the safety screw and push the tower downwards.
  • Page 33: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national For extra safety, it is advisable to install and local safety regulations.
  • Page 34: Operation With Dsm 400 Control Module

    Operation with DSM 400 control module The Miele DSM 400 control module can The components of the central be used to combine the rangehood with extraction system are not supplied as other components. standard by Miele. It enables the following: If in any doubt, the advice of a competent builder must be sought.
  • Page 35: Connection For Air Extraction

    Connection for air extraction – Only use smooth pipes or flexible Important: To avoid the danger of hoses made from non-flammable toxic fumes, please observe the materials for extraction connection. Warning and Safety instructions. – When using an external motor, make This is especially crucial when using sure that the extraction ducting is the rangehood at the same time as...
  • Page 36: Condensate Trap

    Connection for air extraction Condensate trap – If the exhaust air is to be ducted into the open air, the installation of a (optional extra) telescopic wall vent or roof vent is recommended. – If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue.
  • Page 37: Silencer

    Connection for air extraction Silencer . . . With air extraction: (optional extra) The silencer not only reduces noise from the motor outside the house, but also sounds from outside (e.g. traffic noise). For this reason, the silencer must be positioned as close as possible to the ducting exit a.
  • Page 38: Technical Data

    Weight Optional extras for recirculation DA 420 V....42 kg mode: DA 420 V EXT ....38.8 kg - Conversion Kit DUI 31 DA 424 V.
  • Page 40 Alteration rights reserved / 4511 M.-Nr. 09 200 860 / 01...

This manual is also suitable for:

Da 424 v

Table of Contents