Table of Contents Table of Contents 1. Product Code Illumination and Series introduction........2. Specifications....................3. Safety and Precaution..................4 4. Warning and Cautions..................5 5. Installation ......................6 6. Parts and Functions..................9 7. Abnormity Diagnose..................13 8. System Flow Chart................... 15 9.
Table of Contents ES T Abbreviation of Energy Star Through the wall EST10XCM through the wall 115 V Indoor air state outdoor air state Operating condition D.B. ℃ W.B. ℃ D.B. ℃ W.B. ℃ Nominal cooling 26.7 19.4 23.9...
Specification 2. Specification Item Unit EST10XCM Cooling capacity BTU/h 10000 Heating capacity BTU/h Power supply V 60HZ Power input 1020 Cooling Running current BTU/(h·W) Power input Heating Running current BTU/(h·W) Indoor side dB(A) Sound Level Outdoor side dB(A) Height inches...
3. Safety and Precaution WARNING: Following these basic precautions will reduce the risk of fire ,electrical shock ,injury or death when using your air conditioner . 1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply . 2) Proper grounding must be ensured to reduce the risk of shock and fire .
4.Warning and Cautions WARNINGS: Following the safety messages is very important. These messages can save you from being injured or killed. Warning symbols alert you to be careful and means Danger . Always follow instructions to be safe and reduce chances of injury or death .
Fig.A Manufacturer--So the method of installation can be determined. If the installation and slope are suspect,then removal and correct installation of a Haier Wall Sleeve,is recommended. Check the conetents of the accessories supplied with your air conditioner Domestic Air Conditioner...
Page 8
Washer Tapered Spacer Block Board How to install 1.Identify the existing wall sleeve before installing the unit from the insted below. Wall Sleeve Dimensions(inches) Brand Width Height Depth Haier Amana 25-13/32 15-3/4 17-1/2 16-3/4 Haier Amana 25-7/8 15-9/16 White-westinghouse 16,17-1/2...
Page 9
Installation and Accessory Parts Fig.B Mounting tabs can be bent or cut off if not needed.Please use the correct holes to match the sleeve. On 26 3/4”-27” sleeves:Use existing rear grille and redirect louvers to 60 angle as shown in Fig.C Fig.C 5.If the depth of your existing wall sleeve is less than or equal to 20”,skip to step 7.Otherwise,cut the baffles and the support blocks according to length“A”...
6. Parts and Functions °F/°C MODE FILTER RESET MODE SPEED TIMER TEMP/TIME FILTER RESET TEMPERATURE / TIME HIGH CLEAN FILTER CLEAN FILTER INDICATOR ENERGY SAVE COOL POWER DEHUM AUTO RESTART POWER MODE 1. Press mode until you see the indicator light come on next to the desired setting. 2.
Page 11
TO CLEAR TIMER PROGRAM: NOTE: Air conditioner can be either on or off. Press TIMER until Timer indicator light turns off. TO VIEW OR CHANGE THE REMAINING TIME (IN HOURS): TIMER OFF 1. Press the TEMP/TIME up or down arrow button to increase or decrease the time. TIMER ON 1.
Page 12
Using the Remote Cotrol ON/OFF MODE SPEED TIMER TEMP/TIME TEMP/TIME Remote control may differ in appearance from the image shown. NOTE: Remove and discard protective film prior to use. The remote control runs on one CR2025 battery (included). Replace battery after 6 months of use,or when the remote control starts to lose power. To change battery, first remove screw on back panel of remote.
TO CLEAR TIMER DELAY PROGRAM: NOTE: Air conditioner can be either on or off. Press TIMER until Timer indicator light turns off. TO SEE OR CHANGE THE REMAINING TIME (IN HOURS): TIMER OFF: Off or the current room temperature. TIMER ON: 1.
Abnormity Diagnose 7. Abnormity Diagnose 1. Sensor Diagnose: 2 seconds after the sensors open circuit or short circuit, the unit will turn off automatically and the LED will show E0 until the sensors resume. Firstly check whether Terminal CN2 on Pull out the terminals on the indoor the indoor mainboard contact well or mainboard and reinsert them.
Page 15
Abnormity Diagnose 2. Keystroke circuit error diagnose: When power on for the first time, the PCB will check the keystroke circuit, is the sampling value is defferent with the theory value, the LED will show E1, which means failed keystroke circuit. The keyboard is locked and so invalid, but the remote control is working normally.
Wiring Diagram 10. Wiring Diagram WIRING DIAGRAM 0010519540B COMPRESSOR TRANSFORMER FAN MOTOR CAPACITOR B(or W) W(or GR) HERM BL(or R) R(or B) CN30 L M H BL(or R) FUSE1 T3.15A/250VAC COMP.RELAY CN31 CN18 B@(or BR) GR: GRAY BR: BROWN UV LIGHT G(Y/G) BL: BLUE W@(orBL)
Page 20
The End Sincere Forever Haier Group Edited by: GuanLi LiuSuE Haier Industrial Park, No.1, Haier Road 266101, Qingdao, China Signed by: HuangGang Tel: +86 532 88936935 Http://www.haier.com Approved by: ZhangPeng Domestic Air Conditioner...