Haier ESA41J Service Manual
Haier ESA41J Service Manual

Haier ESA41J Service Manual

Model no. esa41j

Advertisement

Quick Links

This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or
repair the product or products dealt with in this service information by anyone else could result in serious injury or death

SERVICE MANUAL

ON/OFF
MODE
SPEED
TIMER
TEMP/TIME
TEMP/TIME
WARNING
All right reserved .Unauthorized copying and distribution is a violation of law
Haier Group
Model No. ESA41J
Feature
Top Discharge Airflow Pattern
Modern Family-look Design
3 Cool Settings, 3 Fan Settings
Easy-to-ins tall Mounting Kit
Easy-Access Washable Filter
Digital Time & Temperature Display
24 Hour on/off Timer
©2009 (Qingdao Haier Air Conditioner General corp.,Ltd)
Order No.$&69

Advertisement

Table of Contents
loading

Summary of Contents for Haier ESA41J

  • Page 1: Service Manual

    ©2009 (Qingdao Haier Air Conditioner General corp.,Ltd) All right reserved .Unauthorized copying and distribution is a violation of law...
  • Page 2: Table Of Contents

    ESA412J Table of Contents Table of Contents 1. Product Code Illumination and Series introduction........2. Specifications....................3. Safety and Precaution..................4 4. Warning and Cautions..................5 5. Installation and Accessory Parts..............6 6. Parts and Functions..................14 7. Abnormity Diagnose..................18 8.
  • Page 3: Product Code Illumination And Series Introduction

    ESA412J Table of Contents 1. Product Code Illumination and Series Introduction 1). Model identification: A: Abbre viation of Energy Star B: The type of refrigerant 4:R410A C: Nominal cooling capacity (BTU/h) with the first two numbers based on one thousand unit D: Desigh code Examples: ESA412J...
  • Page 4: Specifications

    ESA412J Specification 2. Specification Item Unit ESA412J Cooling capacity BTU/h 12000 Heating capacity BTU/h Power supply Ph,V, Hz 1, 115, 60 Power input 1110 Cooling Running current BTU/(h.w) 10.8 Power input Heating Running current BTU/(h.w) ndoor side dB(A) Sound Level Outdoor side dB(A) Height...
  • Page 5: Safety And Precaution

    ESA412J Safety and Precaution 3. Safety and Precaution WARNING: Following these basic precautions will reduce the risk of fire ,electrical shock ,injury or death when using your air conditioner . 1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply . 2) Proper grounding must be ensured to reduce the risk of shock and fire .
  • Page 6: Warning And Cautions

    ESA412J Warning and Cautions 4.Warning and Cautions WARNINGS: Following the safety messages is very important. These messages can save you from being injured or killed. Warning symbols alert you to be careful and means Danger . Always follow instructions to be safe and reduce chances of injury or death .
  • Page 7: Installation And Accessory Parts

    ESA412J Installation and Accessory Parts 5. Installation and Accessory Parts Check the following before you install your air conditioner: 1) The unit is free of all obstructions inside and outside the room e.g. drapes, curtains, furniture, plants, shrubs, bushes, trees, other structures like building, garage etc. Air conditioner must have clear unobstructed airflow through the condenser to remove the heat.
  • Page 8 ESA412J Installation and Accessory Parts Window Installation Window opening measurements: A. Width B. Height MODEL ESA412J Dimension A(inch) Min ”(62.2cm) A(inch) Max 38”(96.5cm) B(inch) Max 149/16”(37cm) Prepare Air Conditioner for Installation Install Top Channel 1. Place the top channel on the top of the air conditioner, lining up the holes in the top channel with the holes in the top of the air conditioner.
  • Page 9 ESA412J Installation and Accessory Parts Install Side Curtains NOTE: Attach curtains to the air conditioner before placing the air conditioner in window. 1. Place the tabbed side of the side curtain in the track on the right-hand side of the air conditioner cabinet. A.
  • Page 10 Installation and Accessory Parts ESA412J 4. Slide the side curtain frame as close to the air conditioner as necessary to lock the side curtain to the frame. Repeat above steps for the left-hand side curtain and frame. Prepare Window for Installation Measure the width of the window opening.
  • Page 11 Installation and Accessory Parts ESA412J A. Side curtain against window channel B. Window sash behind top channel C. Bottom channel in behind windowsill 2. Loosen the screw on the right-hand side of the air conditioner cabinet near the bottom. Slide the side bracket over the screw. 4.
  • Page 12 Installation and Accessory Parts ESA412J 5. Use ” drill bit to drill a starter hole through the holes in the side bracket and windowsill. 6. Using two ” screws, attach the side bracket to the windowsill. 7. Repeat for side bracket installation on the left-hand side of the air conditioner. Attach Side Curtains to Window 1.
  • Page 13 Installation and Accessory Parts ESA412J Top View Bottom View Complete Installation 1. Insert the foam seal behind the top of the lower window sash and against the glass of the upper window. A. Top of lower window sash B. Foam seal 2.
  • Page 14 ESA412J Installation and Accessory Parts Parts Check that all parts are included in parts package. ON/OFF MODE SPEED TIMER TEMP/TIME TEMP/TIME A. Top channel F. ³¹⁄32 ” screws (9) G. Side curtains (2) B. Foam seal C. Side brackets (2) H.
  • Page 15: Parts And Functions

    ESA412J Partd and Functions 6.Partd and Functions Mode Press MODE until you see the indicator light glow for the desired setting. 2. Choose Fan, Cool, Energy Saver or Dehum. ■ Fan—Only the fan runs. Press SPEED to select High, Med or Low fan speed. The display shows the current room temperature.
  • Page 16 ESA412J Partd and Functions TEMP/TIME ■ Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C). NOTE: After 5 seconds, the display will show the current room temperature. Timer Delay To set the Timer for a 1-hour to 24-hour delay until the air conditioner turns off (the air conditioner must be On): 1.
  • Page 17 ESA412J Partd and Functions While the display is showing the remaining time, press the up or down TEMP/TIME button to increase or decrease the time. After 5 seconds, the display will show the current room temperature. Using the Remote Control NOTE:Remote control may differ in appearance.
  • Page 18 ESA412J Partd and Functions Timer To set the Timer for a 1-hour to 24-hour delay before the air conditioner is turned off (the air conditioner must be On): 1. Press TIMER. Timer On indicator light on the air conditioner control panel will flash. TIMER 2.
  • Page 19: Abnormity Diagnose

    ESA412J Abnormity Diagnose 7. Abnormity Diagnose 1. Sensor Diagnose: 2 seconds after the sensors open circuit or short circuit, the unit will turn off automatically and the LED will show E0 until the sensors resume. Firstly check whether Terminal CN2 on Pull out the terminals on the indoor the indoor mainboard contact well or mainboard and reinsert them.
  • Page 20 ESA412J Abnormity Diagnose 2. Keystroke circuit error diagnose: When power on for the first time, the PCB will check the keystroke circuit, is the sampling value is defferent with the theory value, the LED will show E1, which means failed keystroke circuit. The keyboard is locked and so invalid, but the remote control is working normally.
  • Page 21: System Flow Chart

    ESA412J System Flow Chart 8. System Flow Chart Domestic Air Conditioner16...
  • Page 22: Circuit Diagram

    ESA412J Circuit Diagram 9. Circuit Diagram Domestic Air Conditioner...
  • Page 23 ESA412J Circuit Diagram Domestic Air Conditioner...
  • Page 24: Wiring Diagram

    ESA412J Wiring Diagram 10. Wiring Diagram Domestic Air Conditioner...
  • Page 25 ESA412J The End Sincere Forever Haier Group Haier Industrial Park, No.1, Haier Road Edited by: GuanLi Lihao 266101, Qingdao, China E-mail: hractech@haier.com Signed by: YaoHongfang Tel: +86 532 87636960 Http://www.haier.com Approved by: WangXiBo Domestic Air Conditioner...