Gas Control
9)

Removal of Flame rod and spark plug

a. Remove flame rod terminal and tighten span cord.
b. Remove flame rod and spark plug.
c. Remove of High Tension lead
Infinity REU-V2632FFU / HD200I REU-V2632FFUC
Infinity 26i and HD50i

10) Removal of outgoing water thermistor

a. Remove thermistor fixing screw.
b. Remove 2 pin connection outgoing water thermistor
Heat Exchanger Thermistor

11) Removal of heat exchanger thermistor

a. Remove thermistor holder
b. Remove 2 pin connector

12) Removal of air intake thermistor

a. Remove fan motor
b. Remove 2 pin connector of inlet thermistor
c. Remove inlet thermistor (care with O-ring)
d. Thermistor
- 45 -