3 Pin Outlet Socket
1. Switch off power at GPO and unplug power cord from GPO.
2. Unplug the continuous flow water heater 3 pin plug from the socket.
3. Remove the outer jacket screws.
4. Remove the outer jacket and front polystyrene insulation to expose the water heater.
5. Confirm the wiring is as per the wiring diagram on page 6.
6. Disconnect the wiring from the active, neutral and earth connectors.
7. Remove the screw from the centre of the 3 pin socket outlet and remove the bottom
half of the 3 pin outlet socket.
8. Remove the upper half of the 3 pin outlet socket from the water heater.
9. Reassemble in reverse order of above. NOTE: When fitting the replacement 3 pin
outlet socket ensure the bottom half is orientated correctly so the earth pin entry aligns
with the earth socket in the top half of the plug.
10. Refit front polystyrene insulation and outer jacket.
11. Conduct an electrical insulation test. (Refer to page 18).
12. Restore the power supply to the water heater.
TM039 Rheem Water Star Service Instructions REV: A
Date of Issue: 02/09