IMPORTANT SAFETY INSTRUCTIONS
Use
The installation of this unit at non
stationary locations (e.g. ships)
must be performed by a qualified
installer or service agency, in strict
accordance with national and local
safety regulations and standards.
The dryer must not be used without
an exhaust duct.
The dryer must not used without
the lint filter in place or with a
damaged lint filter.
Check regularly on the exhaust
parts (e.g. wall vent duct, louvered
wall vent, bends etc.) for air
permeability. Lint can collect and block
the air flow.
If an exhaust hose is already installed, it
should be checked before connected
to the dryer.
Danger of suffocation or
toxication Adequate ventilation is
essential, especially when another
appliance which also uses the room air
(e.g. gas, oil or coal fired heater,
continuous flow or other water heater) is
installed in the same or an adjacent
room. Allow sufficient room ventilation
by unlockable ventilation openings in
the wall.
Check with your building inspector for a
riskless use to avoid a low pressure of
4 Pa or more.
4
Never connect an exhaust duct to
an active chimney, vent flue or
room venting ductwork. Danger of
toxication by draw back of exhaust
fumes.
When installing multiple dryers to
one collective exhaust duct, a
non-return flap per dryer must be
installed directly to the collective duct.
Otherwise the dryers could be
damaged and the electrical safety
affected.
Keep the area where the dryer is
installed free from lint, dust and
dirt.
Do not install the machine in rooms
where temperatures below freezing
may occur.