Meter Adjustment - Icom IC-706 Service Manual

Hf/vhf
Hide thumbs Also See for IC-706:
Table of Contents

Advertisement

4-5
METER ADJUSTMENT (METER SET MODE)
ADJUSTMENT
ADJUSTMENT CONDITIONS
DISPLAY
OPERATION
S-METER
1 • Enter Meter set mode:
Push [F-2(RX)) to enter S-meter
.Turn power OFF.
USB
setting mode.
.Terminate the [REMOTE) jack with a
CC ,_
L'
P
_'L L
3.5(d) mm mini-plug.
Then advance to the following setting,
·While pushing [P.AMP/ATT] and
E
I:;:~
>::
or::·::
or push [UP)/[DN) to scroll the display.
[TUNE/CALL), turn power ON.
:·:IT
2 • Connect a standard signal generator to
gill
~:;O
I
[:'I!
[:'1
Push [MENU) to set the "SO" level.
[ANT 1] and set as:
1!b••dB
L_. L••• '.' L•• I••
Frequency:
14.15150 MHz
Level
OFF
3 • Set the standard signal generator as:
IJII
~::;I:~
L..EI')FL
Push [MENU) to set the "S9" level.
Level
50 flV
*
(-73 dBm)
Modulation:
OFF
4 • Set the standard signal generator
as~
1.111
·+·i::::i;:jc1f.:::
L.. E:
I.)
i:::
L.
Push [MENU] to set the "+60 dB"
Level
50 mV
*
(-13 dBm)
level.
·The display returns to the same as
that in step 1.
5
Push [MENU
(EXITJ)
to exit meter set mode, or advance to transmit meter setting from step 2 below.
TRANSMIT
1 • Enter Meter set mode:
Push [F-3(TX)] to enter transmit meter
METERS
See "S-METER" item, step 1 above.
USB
setting mode.
CC ,_
L'P
_'L L
Then advance to the following setting,
,.
r'II..1
' 1 ' : :<
or push [UP)/[DN) to scroll the display.
I:
:·:!1
."1:.•
0
"1
..............................
Filter
2 • Connect an RF power meter to [ANT 1].
(:,()
F' I
i...."r
E:
F;:~
r:~:~l
Push [MENU(GOl) to make the
calibration
calibration.
· Transceiver transmits for a while.
..............................
Power meter
3
• Transmit using an external PTT switch.
ii.ll1
~:=;E::
'r
')Oi..
. 1
Set to 90 W using main dial, then
push [MENU).
4 • Transmit using an external PIT switch.
IJi
~::;E:"r
::::il;:j
i..,1
Set to 50 W using main dial, then
push [MENU).
5 • Connect the RF power meter to [ANT 2].
111m
~::;E~T'
·)i..
. 1
Set to 9 W using main dial, then push
• Transmit using an external PTT switch.
[MENU].
6 • Transmit using an external PTT switch.
mUll
~::;E:·T
I:::';
I
Set to 5 W using main dial, then push
..... 1 ....
[MENU) .
..............................
ALC meter
7 • Connect the RF power meter to [ANT 1].
1(111
f~L.C:
~::;
-r
f~
F:
or
Push [MENU] to set ALC reference
• Wait for 2 sec. while receiving for the ALC
level.
function to engage.
· Transceiver transmits for a while.
8
• Connect an audio generator to [MIG]
II III
+.
:;;~
i;:J
(j
E: i....E:i.)E:L.
Push [MENU] to set ALC zone level.
connector and set as:
1111••
1111
Level
100 mV /1.5 kHz
• Transmit using an external PIT switch.
..............................
SWR meter
9 • Connect a 50
Q
dummy load or power
li.Jil
~::;
t.J
i:~~
1.
1....
C)
r~
[)
Push [MENU] to set SWR reference
meter to [ANT 1].
level.
· Transceiver transmits for a while.
9 • Connect a 100
Q
or 25
Q
dummy load to
II! !!D
~:::; 1.1.l1:;~:
~~~
L..e)
rll)
Push [MENU] to set SWR 2 level.
[ANT 1].
1III••dB
· Transceiver transmits for a while.
· The display returns to the same as that in
step
1.
10 Push [F-1
(EXIT)]
to exit Meter set mode.
* This output level of the standard signal generator (SSG) is indicated as SSG's open circuit.
4-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents