5-12 S-METER ADJUSTMENT

1) Select an adjustment item using [2] / [8].
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
S-METER CURVE
NOTE:
[145.1 MHz* (S0 level)]
[145.1 MHz* (S3 level)]
[145.1 MHz* (Full scale)]
[87.5 MHz* (S0 level)]
[87.5 MHz* (S3 level)]
[87.5 MHz* (Full scale)]
S-METER S3 LEVEL
(FM)
[1.01 MHz*]
[15.1 MHz*]
[40.1 MHz*]
[60.1 MHz*]
[220.1 MHz*]
[305.2 MHz*]
[435.1 MHz*]
[535.1 MHz*]
[800.1 MHz*]
; This output level of a standard signal generator (SSG) is indicated as SSG's open circuit.
*; This frequency is an example only, and may differ from the actual frequency displayed on the function display.
All manuals and user guides at all-guides.com
"RECEIVE SENSITIVITY" must be adjusted before "S-METER CURVE" and "S-METER S3 LEVLE."
Otherwise, "S-METER CURVE" and "S-METER S3 LEVLE will not be adjusted properly.
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set as;
Modulation
Deviation
2 • Set the SSG as;
[S0]
Frequency
Level
• Set the SSG as;
[S3]
Level
• Set the SSG as;
[SF]
Level
3 • Set the SSG as;
Frequency
[S0]
Deviation
Level
• Set the SSG as;
[S3]
Level
• Set the SSG as;
[SF]
Level
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set as;
Modulation
Deviation
2 • Set the SSG as;
Frequency
Level
3 • Set the SSG as;
Frequency
Level
4 • Set the SSG as;
Frequency
Level
5 • Set the SSG as;
Frequency
Level
[S3]
6 • Set the SSG as;
Frequency
Level
7 • Set the SSG as;
Frequency
Level
8 • Set the SSG as;
Frequency
Level
9 • Set the SSG as;
Frequency
Level
10 • Set the SSG as;
Frequency
Level
OPERATION
: 1 kHz
: 3.5 kHz
: (Displayed on the function display)
: –8 dBµ (–115 dBm)
: –6 dBµ (–113 dBm)
: –2 dBµ (–109 dBm)
: (Displayed on the function display)
: 52.5 kHz
: 2 dBµ (–105 dBm)
: 5 dBµ (–102 dBm)
: 25 dBµ (–82 dBm)
: 1 kHz
: 3.5 kHz
: (Displayed on the function display)
: –6 dBµ (–113 dBm)
: (Displayed on the function display)
: –8 dBµ (–115 dBm)
: (Displayed on the function display)
: –6 dBµ (–113 dBm)
: (Displayed on the function display)
: –6 dBµ (–113 dBm)
: (Displayed on the function display)
: –6 dBµ (–113 dBm)
: (Displayed on the function display)
: –6 dBµ (–113 dBm)
: (Displayed on the function display)
: –6 dBµ (–113 dBm)
: (Displayed on the function display)
: –6 dBµ (–113 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
5 - 12
VALUE
Push
[BAND].
(Automatic
adjustment)
Push
[BAND].
(Automatic
adjustment)