REMOVING THE INVERTER ASSEMBLY

Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Unplug the refrigerator or disconnect the
power.
2.
Pull the refrigerator out of its mounting
location.
3.
At the rear of the unit, remove the hex-
head screws from the unit compartment
cover and remove the cover.
Inverter Assembly
4.
Remove the hex-head mounting screw
from the inverter assembly and lift the
assembly out of the unit.
Inverter
Assembly
Mounting Screw
5.
Remove the compressor terminal cover
(see step 5 on page 4-16 for the proce-
dure).
6.
Disconnect the inverter output 3-wire con-
nector and ground wire from the compres-
sor.
Assembly
7.
Disconnect the 3-wire and 2-wire connec-
tors from the inverter.
3-Wire Connector
2-Wire Connector
4-17
Green Ground Wire
Compressor
Inverter
Inverter
Connector
Inverter
Assembly