Desa Variable Manually-Controlled Models Owner's Operation And Installation Manual page 8

Unvented (vent-free) natural gas fireplace
Hide thumbs Also See for Variable Manually-Controlled Models:
Table of Contents

Advertisement

AIR FOR
COMBUSTION
AND
VENTILATION
Continued
8
If the area in which the heater may be operated is smaller than
that defined as an unconfined space, provide adequate combus-
tion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1
and 2, Figure 3). You can also remove door into adjoining room (see option 3, Figure 3).
Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion
and Ventilation for required size of ventilation grills or ducts.
Rework worksheet, adding the space of the adjoining unconfined
space. The combined spaces must have enough fresh air to supply all
appliances in both spaces.
Ventilation
Grills
Into Adjoining
Room,
Option 1
Door into
Adjoining
Figure 3 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect
these items directly to the outdoors or spaces open to the outdoors. These spaces include
attics and crawl spaces.
Do not provide openings for inlet or outlet air into attic if attic has a
IMPORTANT:
thermostat-controlled power vent. Heated air entering the attic will activate the power
vent.
Outlet
Air
Inlet
Air
Figure 4 - Ventilation Air from Outdoors
WARNING
WARNING ICON
G 001
WARNING
WARNING ICON
G 001
12"
Ventilation Grills
QQQQ
Into Adjoining Room,
Or
Option 2
Remove
QQQQ
QQQQ
Room,
Option
3
QQQQQ
QQQQ
QQQQQ
12"
Ventilated
Outlet
Attic
Air
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
Ventilated
Inlet Air
Crawl Space
QQ QQ
To Attic
To
Crawl
Space
103281