    CONTENTS 1. GENERAL DESCRIPTION 2. TECHNICAL DATA 3. INSTALLATION 4. FRONT AND BACK PANEL 5. WELDING 6. ROUTINE MAINTENANCE 7. TROUBLESHOOTING 8. WIRING DIAGRAM 9. COMPONENTS AND SPARES 10. ACCESSORIES 11. SAFETY INSTRUCTIONS DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL INCLUDING THE SAFETY INSTRUCTIONS Revision date 11.02.2014 Page 2 of 20...
  • Page 3: General Description

    Thermal overload protection with indicator lights helps prevent machine damage if the duty cycle is exceeded or airflow is blocked. Total Protection function with indicator light prevents machine damage if excess voltage peaks in the IDENTIFY COMPONENTS Unitor Welding Inverter UWI 150 TP, product number 191- 150150 is delivered with Carrying strap and handle...
  • Page 4: Technical Data

    2 TECHNICAL DATA The unique serial number for the machine will be printed here. Always give serial number when ordering spares or in other communication with WSS concerning your machine. Type of welding machine One-phase static transformer rectifier frequency converter, DC output. Processes MMA (Stick Pulsed TIG, pulse frequency 100Hz...
  • Page 5 = Welding current. Range 5 – 150A = Reduced open circuit voltage Is the voltage (excluded any stabilization voltage or arc ignition) found between the output outlets when the welding machine is not welding. This is the voltage a welder can be exposed to between electrode holder and work piece.
  • Page 6: Installation

    Select a suitable location The UWI 150 TP inverter welder has an IP23S rating. Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and out the front of the unit.
  • Page 7: Front And Back Panel

    4 FRONT AND BACK PANEL Description 1. Power on warning. Green light when the machine is connected and switched on. 2. Thermal protection activated. Yellow light indicates that the protection thermostat has cut the output. Do not switch the machine off. The fan will be running and the thermostat resets automatically when the machine has cooled down sufficiently.
  • Page 8: Welding

    5 WELDING MMA (SMAW stick electrode) welding Select MMA welding (selector switch up). 1 Electrode Connect ground (return) cable with good contact to 2 Workpiece the work piece. 3 Arc Select polarity and amperage as recommended for the electrode and start arc as follows: Drag electrode across work piece like striking a Match and lift electrode slightly after touching work.
  • Page 9: Routine Maintenance

    6 ROUTINE MAINTENANCE Checkpoint Action Interval Primary plug Check connections 3 months or more and socket and stretch relief often if needed Check for damage and replace if 3 months or more Primary cable necessary often if needed Primary cable Check for damage 3 months or more stretch relief...
  • Page 10: Troubleshooting

    7 TROUBLESHOOTING SYMPTOM POSSIBLE SOLUTION REASON Mains fuses blown Machine is not plugged in Broken primary cable Primary power No output, no warning does not reach the Cable connection to machine is loose light, fan not running machine Machine not switched on On/off switch damaged Voltage protection Too high input voltage, should be below...
  • Page 11: Wiring Diagram

    8 WIRING DIAGRAM Revision date 11.02.2014 Page 11 of 20...
  • Page 12: Components And Spares

    9 COMPONENTS AND SPARES Revision date 11.02.2014 Page 12 of 20...
  • Page 13 REAR PLASTIC PANEL 045.0000.0007 CABLE CLAMP 045.0002.0001 SUPPLY CABLE 040.0001.0001 TWO-POLE SWITCH 010.0007.0005 PLANAR TRANSFORMER 045.0005.0003 SHUNT For ordering spares please state: Model: UWI 150 TP Serial no: …………. Pos no: …………. Code: .…………. Revision date 11.02.2014 Page 13 of 20...
  • Page 14: Accessories

    10 ACCESSORIES Stick Welding Accessories for UWI 150 TP AutoVision Plus Welding Face Shield with Adjustable Shade 9 To 13 196 767001 Autovision Plus outside cover lens 10 pcs and two frames 196 766997 Long lined welding gloves, 6 pairs...
  • Page 15: Safety Instructions

    11 SAFETY INSTRUCTIONS Arc Welding Hazards The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-5. Read and follow all Safety Standards. Only qualified persons should install, operate, maintain, and repair this unit. During operation, keep everybody, especially children, away.
  • Page 16 FUMES AND GASES can be hazardous. Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. Keep your head out of the fumes. Do not breathe the fumes. If inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases. If ventilation is poor, use an approved air-supplied respirator.
  • Page 17 HOT PARTS can cause severe burns. Do not touch hot parts bare handed. Allow cooling period before working on gun or torch. MAGNETIC FIELDS can affect pacemakers. Pacemaker wearers keep away. Wearers should consult their doctor before going near arc welding, gouging, or spot welding operations.
  • Page 18 MOVING PARTS can cause injury. Keep away from moving parts such as fans. Keep all doors, panels, covers, and guards closed and securely in place. H.F. RADIATION can cause interference. High-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment.
  • Page 19 ECLARATION OF CONFORMITY ₪ ₪₪₪₪₪₪₪₪₪₪ ₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪ UNITOR WELDING We hereby state that the machine type INVERTER UWI-150 TP ₪₪₪₪₪₪₪₪₪ ₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪ ₪ ₪₪₪₪₪₪₪ 2004/108/ 2006/95/ is in compliance with the directives 2011/65/EU ₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪₪ 60974-1 and that the following standards apply 60974-10 ₪₪₪₪₪₪₪...
  • Page 20 Fraser/surrey Gaspe Gros Caouna Halifax Hamilton Harbour Grace Holyrood Kitimat Long Pond Marytown Montreal Nanaimo New Instruction manual Westminster Bc Pictou/halifax Pointe Aux Pic.quebec Port Alfred Port Cartier Port Colborne Port Hawkesbury Port Mellon Port Moody Port Of Quebec Port Weller Powell River Prince Rupert Roberts Bank Saint John Sarnia, Ontario Sept Iles Seven Islands Sorel Souris/ halifax Squamish St.