Set Temperature Rise - Carrier 58MCB Installation, Start-Up, And Operating Instructions Manual

4-way multipoise fixed-capacity condensing gas furnace for sizes 040-140, series 100
Table of Contents

Advertisement

INLET
PRESSURE TAP
Fig. 46—Redundant Automatic Gas Valve
Fig. 47—Burner Orifice
Table 15—Altitude Derate Multiplier for U.S.A.
ALTITUDE
% OF
(FT)
DERATE
0—2000
2001—3000
4—6
3001—4000
6—8
4001—5000
8—10
5001—6000
10—12
6001—7000
12—14
7001—8000
14—16
8001—9000
16—18
9001—10,000
18—20
* Derate multiplier factor is based on midpoint altitude for altitude range.
ON AND
OFF SWITCH
GAS
PRESSURE
REGULATOR
ADJUSTMENT
BURNER
ENCLOSURE
REFERENCE
PRESSURE
TAP
MANIFOLD
PRESSURE TAP
BURNER
ORIFICE
DERATE MULTIPLIER
FACTOR
0
1.00
0.95
0.93
0.91
0.89
0.87
0.85
0.83
0.81
EXAMPLE: (0—2000 ft altitude)
Furnace input from rating plate is 100,000 Btuh.
Btu heating input = Btu/cu ft X cu ft/hr
Heating value of gas = 975 Btu/cu ft
Time for 1 revolution of 2-cu ft dial = 70 sec
Gas rate = 103 cu ft/hr (from Table 16)
Btu heating input = 103 X 975 = 100,425 Btuh
In this example, the orifice size and manifold pressure
adjustment is within ±2 percent of the furnace input rate.

SET TEMPERATURE RISE

UNIT DAMAGE HAZARD
Failure to follow this caution may result in overheating the
heat exchangers or condensing flue gases in heat exchanger
A95622
areas not designed for condensate.
Temperature rise must be within limits specified on unit
rating plate. Recommended operation is at midpoint of rise
range or slightly above.
Determine and adjust air temperature rise as follows:
1. Place thermometers in return and supply ducts as close to
furnace as possible. Be sure thermometers do not see heat
exchanger so that radiant heat does not affect readings. This
practice is particularly important with straight-run ducts.
Table 16—Gas Rate (Cu Ft/Hr)
SECONDS
FOR 1
REVOLUTION
10
11
12
13
A93059
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
51
SIZE OF TEST DIAL SECONDS
FOR 1
1
2
5
REVOLUTION
cu ft
cu ft
cu ft
360
720
1800
50
327
655
1636
51
300
600
1500
52
277
555
1385
53
257
514
1286
54
240
480
1200
55
225
450
1125
56
212
424
1059
57
200
400
1000
58
189
379
947
59
180
360
900
60
171
343
857
62
164
327
818
64
157
313
783
66
150
300
750
68
144
288
720
70
138
277
692
72
133
267
667
74
129
257
643
76
124
248
621
78
120
240
600
80
116
232
581
82
113
225
563
84
109
218
545
86
106
212
529
88
103
206
514
90
100
200
500
92
97
195
486
94
95
189
474
96
92
185
462
98
90
180
450
100
88
176
439
102
86
172
429
104
84
167
419
106
82
164
409
108
80
160
400
110
78
157
391
112
76
153
383
116
75
150
375
120
73
147
367
124
SIZE OF TEST DIAL
1
2
5
cu ft
cu ft
cu ft
72
144
360
71
141
355
69
138
346
68
136
340
67
133
333
65
131
327
64
129
321
63
126
316
62
124
310
61
122
305
60
120
300
58
116
290
56
112
281
54
109
273
53
106
265
51
103
257
50
100
250
48
97
243
47
95
237
46
92
231
45
90
225
44
88
220
43
86
214
42
84
209
41
82
205
40
80
200
39
78
196
38
76
192
38
75
188
37
74
184
36
72
180
35
71
178
35
69
173
34
68
170
33
67
167
33
65
164
32
64
161
31
62
155
30
60
150
29
58
145