Note: Some local codes require this condensate to be neutralized prior to disposal.
See illustrations below for proper drain connections.
LEFT DRAIN & VENT
RIGHT DRAIN & VENT
HORIZONTAL LEFT
HORIZONTAL RIGHT
GAS PIPING & GAS PIPE CAPACITY TABLE
Check the rating plate to make certain that the unit is equipped to burn the type of gas supplied. Care
should be taken after the installation of this appliance that the gas control valve is not subjected to
high gas supply line pressure. In making connections, avoid strains as they may cause noise and
damage the controls. Always use a back-up wrench when tightening the gas supply pipe to the gas
control valve. Check for leaks in the gas supply piping using soap bubbles or other approved method.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. THIS PRACTICE MAY CAUSE A
FIRE, EXPLOSION, BODILY HARM OR PROPERTY DAMAGE.
IO-176
13