Condenser (air cooled)

The condenser should only have to be replaced if it has been physically damaged to the point that repair is not
practical. Use a fine comb to straighten bent/pushed-in areas. If replacement if necessary, the following equip-
ment is required: vacuum pump, refrigeration manifold with gauges, brazing equipment and various hand tools.
The replacement procedure has two steps: CABINET REMOVAL and CONDENSER REPLACEMENT.
Cabinet Removal
1. Remove ice from the hopper and all panels and plastic parts.
2. Disconnect electrical power to the unit.
3. Release refrigerant charge from the system through ports into an appropriate container/reclaim system.
4. Disconnect harness from gate solenoid (upper front) and dispenser push button switch.
5. Disconnect harness from the bin t' stat and air pump. Make sure that the harness is not secure to the cabi-
net.
6. Remove clear hoses from the discharge and suction of the air pump.
7. Remove the pins from behind the front cabinet flanges at the sink.
8. Remove sink.
9. Remove bracket mounting evaporator assembly to the cabinet.
10. Loosen two (2) 1/4 x 20 hex head screws securing the evaporator mounting bracket to the base. Tilt evapo-
rator assembly towards the back to remove the evaporator ice chute from the hopper partition.
11. Remove partition (4 screws).
12. Remove screw securing cabinet to the base.
13. Lift the cabinet.
Condenser Replacement (air-cooled)
1. Remove screws mounting condenser shroud from the base and condenser.
2. Remove screws mounting condenser to the base.
3. Unbraze refrigerant lines from inlet and outlet of condenser.
4. Replace condenser.
5. It is also recommended to replace the filter drier.
6. After brazing, perform leak test of the new brazing joints.
7. Evacuate the system.
8. Charge the system to the name plate specification (1 lb. of r-22).
9. Install cabinet - Use reverse order of step 1.
10. Run the icemaker and check operation pressure in relation to the ambient temperature.
11. Install sink, panels and plastic parts.