Grounding Generator To Truck Or Trailer Frame; Installing Exhaust Pipe - Miller Trailblazer 302 Diesel Owner's Manual

Diesel engine driven welder / generator
Hide thumbs Also See for Trailblazer 302 Diesel:
Table of Contents

Advertisement

5-3. Grounding Generator To Truck Or Trailer Frame

!
Always ground generator frame to
vehicle frame to prevent electric
shock and static electricity hazards.
!
Also see AWS Safety & Health Fact
Sheet No. 29, Grounding of Portable
And Vehicle Mounted Welding Gen-
erators.
!
Bed liners, shipping skids, and
some running gear insulate the

5-4. Installing Exhaust Pipe

Tools Needed:
1/2 in.
.
1
2
GND/PE
3
welding generator from the vehicle
frame. Always connect a ground
wire from the generator equipment
grounding terminal to bare metal on
the vehicle frame as shown.
!
Use GFCI protection when operat-
ing auxiliary equipment. If unit does
not have GFCI receptacles, use
GFCI-protected extension cord.
A complete Parts List is available at www.MillerWelds.com
1
Equipment Grounding Terminal (On
Front Panel)
2
Grounding Cable (Not Supplied)
3
Metal Vehicle Frame
Connect cable from equipment ground
terminal to metal vehicle frame. Use #8
AWG or larger insulated copper wire.
.
Electrically bond generator frame to ve-
hicle frame by metal-to-metal contact.
!
Stop engine and let cool.
!
Do not blow exhaust toward
right side of unit where air inlet
is or air cleaner may require
frequent service. Point ex-
haust pipe in desired direction
but always away from front
panel and direction of travel.
rot_grnd2 2011−04 − 800 652-D
804 196-A / Ref 216 171-B
OM-217 454 Page 19