Operation (Manual Controller); Starting, Stopping And Operating Instructions; Starting; Stopping - Carrier AC310 Operation And Service Instructions Manual

Rooftop air conditioning units with bt324 carrier sutrak digital display (csdd) or 280p/282p electronic thermostat
Table of Contents

Advertisement

2.1 STARTING, STOPPING AND OPERATING
INSTRUCTIONS
The control switches supplied by Carrier Transport Air
Conditioning will be marked with international symbols
(See Figure 2.1).
Before starting, electrical power must be available from
the bus power supply.
150 Amp @12 VDC or125 Amp @ 24 VDC from a fuse in
the battery compartment supplies power for the clutch,
evaporator and condenser assemblies.
LOW -- -- -- HIGH
OFF
2.2 PRE- -TRIP INSPECTION
After starting system, allow system to stabilize for ten to
fifteen minutes and check for the following:
04/08
SECTION 2

OPERATION (MANUAL CONTROLLER)

ON

Figure 2.1 Control Switches (Typical)

2--1

2.1.1 Starting

a. If the engine is not running, start the engine.
b. Actual start sequence depends on the operating co-
trol supplied. If only an ON/OFF switch is supplied,
place the switch in the ON (fan symbol) position to
start the system in the automatic mode.
c. After the pre--trip inspection is completed, the
switches may be set in accordance with the desired
control modes.
d. If low or high speed evaporator fan speed is desired,
press the FAN SPEED (fan symbol) button to bring
speed to the desired level.

2.1.2 Stopping

Placing the ON/OFF (Snowflake) switch in the OFF
position will stop the system operation by removing
power to the Logic Board.
COOL
Temperature Control
a. Listen for abnormal noises in compressor or fan mo-
tors.
b. Check compressor oil level (05G Compressor only).
c. Check refrigerant charge. (Refer to section 5.8.1 )
HEAT