1. S AFETY INFORMATION Keep Children Away: Do not allow children to play with, or around this unit. It may result in injury. Be sure the unit is inaccessible to children when unattended. Keep Unit Grounded: Always operate the unit with a grounding plug and a grounded electrical outlet.
2. G ENERAL ADVICES Before putting your dehumidifier into operation for the first time, the instructions manual should be studied carefully. After receiving the unit, you should check your dehumidifier for any transport damage. In case of damage, you should inform and make a note of it on the forwarding documents.
4. I NSTALLATION AND TRANSPORT For installation and transport, the following instructions must be considered: Both air filters and slats located on the dehumidifier’s laterals must not be covered! Before moving the dehumidifier’s place of installation, the appliance must be switched off in the power button.
5. C ONTROL PANEL Item Designation Item Designation Power button Power lamp Fan speed selector Water tank full lamp Room humidity control Relative humidity control display...
6. O PERATING INSTRUCTIONS ATTENTION Operate this dehumidifier only in the upright position. Plug in to a standard outlet with the correct voltage and current for the unit. If the unit shuts off for any reason allow it to rest for five minutes before restarting it.
To use the water pump or the hoses, for draining the condensate, you should proceed as follows: Remove the tank from the tank compartment. Fasten the hose provided with the equipment and then attach it to the water pan outlets underneath the evaporator. If possible, the hose should be fastened using a hose clamp.
10. O PERATING CONDITIONS This dehumidifier can be operated within a temperature range from +1 to +35°C and with a relative humidity of 30% to 90%. It was designed for application in museums, libraries, schools, residential buildings and many other places. 11.
12. T ROUBLESHOOTING Trouble Cause Solution Plug in the unit; check power at No power to the unit outlet Unit does not operate Switch not turned ON Turn ON the switch Water collecting tank The water collecting tank must completely filled be emptied and installed again Under these conditions the The ambient...
Page 11
Trouble Cause Solution The air dryer will cut in again The fan is out of automatically after some The dehumidifier is at minutes. If not, the malfunction operation the stage of defrosting must be eliminated by a specialized workshop Defective control Contact a specialized workshop assembly Unit continuously in...
13. M AINTENANCE Always turn off the power and disconnect the main cable before performing maintenance procedures. All the service procedures below are to be executed with the unit unplugged. Perform before each use or as needed. INSPECT ELECTRICAL SYSTEM Inspect the electrical cord for damage at regular intervals.
16. I NDIVIDUAL COMPONENTS Item Designation Item Designation Control PCB Left side plastic panel Compressor Right side plastic panel Evaporator/Condenser Water pan Motor fan Wheel Filters Caster wheel Filter’s support Plug holder Stainless steel front Water collector cover Base plate Stainless steel top cover Stainless steel back Water collector base plate...