 Enter password: <Release Key of far end system>
 Go to the remote folder, type "cd remote"
 Upload the software file, type put <s0xxxxxx.pkg>
 Wait until the following is shown:
226 Closing data connection.
5437569 bytes sent in 808.01 seconds (6.73 Kbytes/sec)
ftp>
 Restart the far end system.
The far end system should now be upgraded. For further information, please contact your
TANDBERG representative.
Custom logos
 Go to the folder where your logo is located.
 Type "ftp <IP-address of your local system>".
 Go to the user folder, type "cd user".
 Upload the logo, type "put <startup.jpg>".
The new logo will be displayed the next time you restart your system. Logo max size: E2 and
above: 704x480, B7 and above: 320x200, file-format: jpg. If the file is too large, no logo will be
displayed.