Regency P121 Owners & Installation Manual page 16

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
Horizontal Venting with Two (2) 90
Option
V
A)
1' (305mm) Minimum
B)
2' (610mm) Minimum
C)
3' (914mm) Minimum
D)
4' (1.22m) Minimum
E)
5' (1.5m) Minimum
F)
6' (1.86m) Minimum
With the above options, maximum total pipe length if 37 feet with
minimum of 6 feet total vertical and maximum 15 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 3
Horizontal Venting with Two (2) 90
Option
V
A)
1' (305mm) Min. 1' (305mm) Max. 3' (914mm) Max.
B)
2' (610mm) Min. 3' (0.91m) Max.
C)
3' (914mm) Min. 5' (1.5m) Max.
D)
5' (1.5m) Min.
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 4
16
o
Elbows
H + H1
2' (610mm) Maximum
5' (1.5m) Maximum
8' (2.4m) Maximum
11' (3.35m) Maximum
14' (4.27m) Maximum
15' (4.5m) Maximum
o
elbows is required.
o
Elbows
H
H + H1
6' (1.86m) Max.
9' (2.7m) Max.
8' (2.4m) Max.
12' (3.6m) Max.
o
elbows is required.
Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace
Horizontal Venting with Three (3) 90
Option
V
A)
2' (610mm) Min. 1' (305mm) Max. 3' (914mm) Max.
B)
3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max.
C)
4' (1.22mm) Min. 5' (1.5m) Max.
D)
5' (1.5m) Min.
7' (2.13m) Max.
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 5
Horizontal Venting with Three (3) 90
Option
V + V1
A)
2' (610mm) Minimum
B)
3' (914mm) Minimum
C)
4' (1.22m) Minimum
D)
5' (1.5m) Minimum
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 6
o
Elbows
H
H + H1 + H2
9' (2.7m) Max.
12' (3.6m) Max.
o
elbows is required.
o
Elbows
H + H1
3' (914mm) Maximum
6' (1.86m) Maximum
9' (2.7m) Maximum
12' (3.6m) Maximum
o
elbows is required.

Advertisement

Table of Contents
loading

This manual is also suitable for:

P121rcP121lcP131

Table of Contents