Clearances; Pre-Installation; Installation Steps; Electrical Connections - Lennox Hearth Products MPE-36R Installation And Operating Instructions Manual

Merit plus series 36" electric fireplace
Table of Contents

Advertisement

FIREPLACE SPECIFICATIONS
Cat. No. H1534
Model: MPE-36R
Description: Merit Plus Electric Fireplace,
36" Radiant
Shipping Weight: 90 lb.'s (41 KG)
Packaging:
44-3/4" x19-1/2" x 34-1/4"
(1135 mm x 495 mm x 870 mm)
17.30 cu. ft.
Power Requirements:
(120 Volt, 60 Hz.)
Rated Wattage - 1600 Watts
Amperage - 13.33 Amps
(240 Volt, 60 Hz.)
Rated Wattage - 3000 Watts
Amperage - 12.5 Amps
Blower CFM: 83 CFM
(120 V): 5,461 BTU/HR
(240 V): 10,239 BTU/HR
MINIMUM CLEARANCES TO COMBUS-
TIBLES
This appliance is a zero-clearance design and
is approved to be framed in with combustible
materials (up to the edge of the appliance).
A drywall lip at the top of the fi replace and 4
nailing fl anges on the sides of the appliance is
provided to facilitate installation.

Clearances

Sides
0 inches - 0 mm
Floor
0 inches - 0 mm
Top
0 inches - 0 mm
Table 2
Mantel Clearance: Combustible and Non-com-
bustible mantels may be installed at any height
above the top of the face of fi replace.
Hearth Protection: A hearth is not mandatory,
but it is recommended for aesthetic purposes.
Secure the hearth extension to the fl oor to
prevent possible shifting. Do no block the air-
fl ow beneath the appliance (read the following
WARNING).

PRE-INSTALLATION

Before You Start
Check appliance for any concealed damage.
DETAILED INSTALLATION STEPS
1. Complete the framing opening to the dimen-
sions specifi ed in Figure 2.
2. Prepare the connections to power source:
120 Volt Connections - Locate the power
cord on the left side of the unit and connect
it to the outlet installed during the framing
(see Figure 2). Verify that the power to the
receptacle is off.
Hard wired installation:
Ensure that there is a minimum of 8" of the
service cable for connection to the junction
box on the fi replace.
- Loosen four screws to remove the junction
box cover plate.
- Disconnect and remove the 120 Volt power
cord from the fi replace wires.
- Position the fi replace into the framed-in
opening. Attach fi replace to frame using
nailing fl anges provided.
- Complete the wiring to the fi replace as
shown on Page 10.
- Place all wire connectors inside the junction
box.
- Attach junction box cover plate with four
screws.
240 Volt Connections - Ensure that there
is a minimum of 8" of the service cable
for connection to the junction box on the
fi replace.
- Loosen four screws to remove the junction
box cover plate.
- Disconnect and remove the 120 Volt power
cord from the fi replace wires.
- Position the fi replace into the framed-in
opening. Attach fi replace to frame using
nailing fl anges provided.
- Complete the wiring to the fi replace as
shown on Page 11.
- Place all wire connectors inside the junction
box.
- Attach junction box cover plate with four
screws.
The fi replace wires L1, L2, N, N1, N2 and
G are attached to the rear of the junction
box cable clamp for easy access.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3. Wire a dedicated, properly fused circuit with
an Amp rating for the appropriate voltage
(120 V - 15 Amps or 240 V - 20 Amps).
A dedicated circuit is required to prevent
overloading a house circuit in cases of having
multiple appliances on the same circuit.
Use an outlet that is protected by a ground
fault circuit interrupter where required by
electrical code.
4. (If applicable) Make wall mount wall switch
or wall thermostat connections as outlined
on Pages 11 & 12.
5. Perform a function test. See Manual Control
Panel Operation on Page 6 and Remote
Control Operation on Page 7.

ELECTRICAL CONNECTIONS

Refer to the electrical diagrams on Pages 10
to 14.
WARNING
Electrical wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of fi re, electrical
shock and injury to individuals.
IMPORTANT
Any electrical re-wiring of this
appliance must be done by a
qualifi ed electrician.
WARNING
Do not use this fi replace if any
part of it has been underwater.
Immediately call a qualified
service technician to inspect the
fi replace and replace any part of
the electrical system which has
been under water.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents