Chimney Support Installation; Chimney Chase And Multiple Terminations; Chimney Adaptor - Superior WRT4820WS Installation And Operation Instructions Manual

Epa wood-burning fireplaces
Table of Contents

Advertisement

CHIMNEY SUPPORT INSTALLATION

Universal Roof Support
When installing a support, slightly lift the chimney system so the weight
will lie on the support, not on the fireplace to reduce expansion noises.
This support has three possible uses:
1. For ASHT / HT6103+ and S-2100+ / HT6000+, it must be used on a
roof to support the chimney
2. It may be used on a floor, ceiling or roof above an offset to support
the chimney above the offset.
3. It may be used on a floor, ceiling or roof as a supplementary sup-
port.
Table 6 gives maximum height of supported chimney.
NOTE: For the AC chimney
feet (12 m) instead of the universal roof support (ST
For roof support installation, refer to the instructions provided with the
support.
Universal Offset Support
This support is used to support the chimney above an offset. When
the chimney offset is used to traverse a wall this support may be used
on the wall to support the chimney. The maximum heights are given in
Table 6. For offset support installation, refer to the instructions provided
with the support.
CHIMNEY MODEL
*
ASHT / HT6103+ (6" dia).
S-2100+ / HT6000+ (6" dia).
AC (6" dia).
Table 6

CHIMNEY CHASE AND MULTIPLE TERMINATIONS

For the purpose of this manual, a chimney chase is considered a part of
the chimney system rather than part of a building. The termination must
be placed a minimum of 18" (460 mm) above the chase.
For installations where more than one chimney is located in the same
chase or within the same area, we suggest that their terminations be
separated by at least 16" (410 mm) horizontally, and 18" (460 mm) verti-
cally. This separation is to prevent smoke migrating from one chimney
to another (see Figure 37).
22
*
.
*
, a support section must be used every 40
*
).
*
*
MAXIMUM HEIGHT OF
SUPPORTED CHIMNEY
OFFSET SUPPORT
ROOF SUPPORT
28 feet (8.54 m)
29 feet (8.84 m)
18 feet (5.49 m)
20 feet (6.1 m)
40 feet (12.19 m)
50 feet (15.20 m)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
18" (460 mm)
16" (410 mm)
Figure 37

CHIMNEY ADAPTOR

(S-2100+ / HT6000+) CANADA ONLY
*
The fireplace is normally supplied with a chimney adaptor suitable for the
ASHT / HT6103+ chimney
. If you want to install a S-2100+ / HT6000+
*
chimney, an adaptor is available (6UCA
section will also be required if AC chimney
Chimney Adaptor
-
*
Canada only
Figure 38
18" (460 mm)
18" (460 mm)
16" (410 mm)
) (Figure 38). A separate starter
*
is installed.
*
Available from Security Chimneys™
*