Removing the vertical air flow louver
CAUTION
The horizontal air flow louvers cannot be released from the vertical air flow louver.
1.
Open the moving panel, and support it with the panel support.
2.
Open the vertical air flow louver.
3.
Insert a flathead screwdriver into the gap of the louver fixture on the right and left ends of the vertical air flow louver, and turn in
the counter-clockwise direction to remove.
4.
After pressing in the right and left connector joints, remove the vertical air flow louvers. Press in the right-side joint first before
pressing in the left-side joint.
Attaching the vertical air flow louvers
1.
Attach the vertical air flow louvers by inserting the connector joints in the order of left, right, and center.
2.
Secure the horizontal air flow louvers to the connector joints.
• After pressing in the connector joints, align the positions of the connector joints and connectors.
Press the louver fixture downwards to lock it into place.
• After attaching, move the louver fixture from side to side to check that the connector joint does not come off.
EN
Removing the louver fixture
(Left side)
Louver fixture
Horizontal air flow
louvers
Air flow louver
Flathead screwdriver
Removing the louver fixture
Louver fixture
Connector joints
Connectors
Horizontal air flow
louvers
Air flow louver