Goodman GRL SERIES Installation Instructions Manual page 14

For upflow high efficiency condensing two-stage gas furnaces
Table of Contents

Advertisement

Method 2 (not shown)
One permanent opening, located
within 12 inches of the top of the
enclosure, shall be permitted
where the equipment has
clearances of at least 1 inch from
the sides and back and 6 inches
from the front of the appliance.
The opening shall directly
communicate with the outdoors or
communicate through a vertical or
horizontal duct to the outdoors or
spaces (crawl or attic) that freely
communicate with the outdoors,
and shall have a minimum free
area of:
a. 1 square inch for each 3,000
BTUH of the total input rating of all
equipment located in the enclosure
and
FIGURE 8
COMBUSTION AIR FITTING
14
BTUH
Input
45,000
15.00 square inches
60,000
16.67 square inches
90,000
30.00 square inches
b. Not less than the sum of the
areas of all vent connectors in the
confined space.
If unit is installed where there is an
exhaust fan, sufficient ventilation
must be provided to prevent the
exhaust fan from creating a negative
pressure.
Combustion air openings must not be
restricted in any manner.
CONSULT LOCAL CODES FOR
SPECIAL REQUIREMENTS.
UPFLOW
ATTACH DOUBLE ELBOW TO TOP INLET
AIR OPENING OR 90° ELBOW TO SIDE
INLET AIR OPENING TO PREVENT
ACCIDENTAL BLOCKAGE OF INTAKE
OPENING. PLUG OPENING NOT USED.
EXHAUST
Free Area
Round Pipe
Each Opening
Size
4"
5"
6"
2" PVC
DOUBLE
ELBOW
TOP
OPTION
2" PVC ELBOW
SIDE
OPTION
I337
CONNECTION TO
FURNACE
IMPORTANT: When indoor
combustion air is used, the inlet air
opening at the furnace must be
protected from accidental blockage.
(See Figure 8).