Seawater Pump - Kohler 4EFOZ Operation Manual

Marine generator sets
Hide thumbs Also See for 4EFOZ:
Table of Contents

Advertisement

3.8.5

Seawater Pump

The belt-driven seawater pump is located on the service
side of the generator set.
seawater pump impeller at the interval specified in the
service schedule. Follow the instructions included with
the impeller kit. If the instructions are not included with
the kit, use the following procedure:
Impeller Inspection and Replacement Procedure:
1. Close the seacock.
2. Remove the seawater pump coverplate.
Figure 3-7.
3. Remove the impeller.
4. Inspect the impeller for damaged, cracked, broken,
missing or flattened vanes. The impeller vanes
should be straight and flexible. See Figure 3-8.
Replace the impeller if it is damaged.
1
10
9
8
7
1. Seawater pump
2. Coverplate
3. Gasket
4. Impeller
5. Bearing
6. Housing
Figure 3-7 Seawater Pump, Typical
TP-6068 10/02
Check and change the
11
2
3
4
5
6
TP-6053
7. Pulley
8. Drive shaft
9. Washer
10. Nut
11. Mechanical seal,
if equipped
1. Flattened vane
2. Crack
See
3. Broken vane
Figure 3-8 Worn Impeller
5. Lubricate the impeller with soapy water before
installation.
6. Install the impeller.
Note: During installation push and rotate the
impeller in the same direction as the engine
rotation until it is thoroughly seated in the
impeller housing.
7. Inspect the coverplate and gasket for corrosion
and/or damage.
necessary.
8. Lubricate the gasket with silicon grease and attach
the gasket and coverplate to the seawater pump
housing.
9. Open the seacock.
10. Start the generator set and check for leaks.
11. Stop the generator set and repair leaks or replace
damaged or worn components.
1
2
3
Replace components as
Section 3 Scheduled Maintenance
TP-6053
m:sm:003:008
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents